How should the electrical power and speed control switches be connected to the ventilation unit?

The 230V power supply connects to the Phase (L), Neutral (N), and Earth terminals. Speed and sensor controls operate at 12V and must be wired to the numbered terminals (1 to 9) on the internal electrical board. Speed is managed via a push button or hygrostat; standard two-position switches are not recommended.

B K

Jennifer B.

How to wire the power supply and speed control switches to the unit?

Connect the main power supply to the 230V terminals: Neutral to blue, Phase to brown, and Earth to green/yellow. Speed control switches and sensors operate on a 12V circuit and must be connected to the numbered terminal block (1-9) on the internal electrical board, never directly to the main power supply or meter.