Schneider Electric Unités de contrôle Micrologic 5.0 P to 7.0 P Mode d'emploi

PDF
Document
Micrologic 5.0 P, 6.0 P, 7.0 P: Guide utilisateur + IA | Fixfr
/

User questions

E F

James E.

What types of data are accessible via the COM communication option on the Micrologic P control unit?

The COM communication option allows remote access to various data for the Micrologic P control unit. This includes detailed Measurements (currents, voltages, powers, energies, frequency, power factor), Configuration/Maintenance parameters (date/time, passwords, ID, calculation algorithms, battery charge, fault/alarm histories, operation counters, relay settings, logs), and Protection parameters (rated current, neutral protection, various protection settings like Long/Short Retard, Instantaneous, Ground fault, Differential Current, Current unbalance, Voltage, and other protections).

E F

James E.

What data is accessible remotely through the COM communication option on the Micrologic P control unit?

Through the COM communication option, the Micrologic P control unit allows remote access to various data, including:

  • Measurements: Instantaneous and averaged currents (maxima, minima, unbalance), voltages (simple, compound, average, unbalance), active, reactive, and apparent powers (instantaneous, averaged, maxima, minima), total active and reactive energies, network frequency, and power factor. It also provides update dates for averaged currents, power, and energies.
  • Configuration / Maintenance: Date and time updates, measurement module password, control unit identification code and name, measurement calculation algorithm selection, active power sign convention and total energy measurement, integration window calculation principle and duration, battery charge indication, fault and alarm histories, operation counter, contact wear, relay assignment and configuration, and maintenance logs.
  • Protection: Circuit breaker nominal current, neutral protection type, parameters for Long Retard I2t and Idmtl, Short Retard, Instantaneous, Earth, and Differential Current protections. It also includes parameters for current unbalance, earth alarm, maximum current, voltage protections (Umin, Umax, Udeseq), and other protections (rPmax, Fmin, Fmax, phase rotation).
E F

James E.

What types of data are accessible remotely via the COM communication option for the Micrologic P control unit?

Data accessible includes measurement parameters (currents, voltages, powers, energies, frequency, power factor), configuration/maintenance parameters (date/time update, password, unit ID, algorithm selection, battery charge, fault history, contact wear, relay assignment), and protection parameters (breaker nominal current, neutral protection, various protection settings like Long Retard, Short Retard, Instantaneous, Earth, Differential Current, current unbalance, voltage protection, and other protections).

E F

James E.

What data is accessible via the COM communication option?

The COM communication option allows access to measurement, configuration, maintenance, and protection parameters of the Micrologic P control unit. Accessible data includes: Measurements (e.g., instantaneous currents, voltages, active/reactive/apparent powers, energies, network frequency, power factor), Configuration/Maintenance (e.g., date/time update, passwords, unit identification, fault/alarm history, contact wear), and Protection (e.g., circuit breaker nominal current, neutral protection type, various delay and differential protection parameters, voltage protections).