Minebea Intec Process Indicator X2 PR 5310 Manuel du propriétaire

PDF
Document
Minebea Intec X2 PR 5310 Manuel technique | AI Chat & PDF | Fixfr
/

User questions

L T

John L.

Is a reading of 0.1 kg normal after zeroing the scale?

Yes, a reading of approximately 0.1 kg after zeroing is possible. The device uses a zero-setting range (ZESrnG) and an automatic zero-tracking function to compensate for minor deviations within the unit's specific metrological limits.

L T

John L.

What are the functions of the buttons on the device interface?

According to the document, the keys located on the indicator's keypad (front panel) have the following functions:

  • Indication keys:
    • Tare: records the current gross weight in tare memory (if weight is stabilized and no error).
    • Select weight type: switches between Net, Gross, and Tare.
    • Zero: resets gross weight to zero (under certain stability conditions).
    • Print: initiates a print.
    • Test: analog key, weighing function.
  • Menu/Navigation keys:
    • Setup Menu: calls the Setup menu.
    • Exit: closes and exits the current menu.
    • OK: confirms input or selection.
    • Cursor left / right / up / down: navigation in menus, parameter selection, and digit modification.
L T

John L.

After performing a zero-setting operation, is it normal for the display to show a small value such as 0.1 kg?

According to the document, it is entirely possible for the display to show a value such as 0.1 kg (or a small deviation) after zeroing. Indeed, the zeroing function has a tolerance range called the zeroing range (parameter ZESrnG) as well as an automatic verification zone that allows compensating for small deviations (within the scale division and device parameters). Warning regarding the use of general arguments: While the document describes tolerance and zeroing mechanisms, the exact interpretation of a specific 0.1 kg display depends on the precise settings of your installation (such as the StEP division or the configured zeroing range). Using purely general arguments without considering the metrological parameters specific to the X2 PR 5310 device may lead to erroneous interpretations of weighing accuracy.

L T

John L.

What is the function of the interface buttons and is a non-zero reading normal after resetting?

The interface includes buttons for Tare, Zeroing, Type Selection (Net/Gross/Tare), Printing, and Testing, along with navigation arrows. After pressing zero, a small reading like 0.1kg may appear; this is normal as the device compensates for small deviations within a specific tolerance range (ZESrnG).

L T

John L.

What are the functions of the buttons on the indicator interface?

D’après le document, les touches situées sur le clavier de l'indicateur (façade avant) ont les fonctions suivantes :

  • Touches d'indication :
    • Tarage : enregistre le poids brut actuel dans la mémoire de tare (si le poids est stabilisé et qu'il n'y a pas d'erreur).
    • Sélectionner le type de poids : bascule entre Net, Brut et Tare.
    • Mise à zéro : remet le poids brut à zéro (sous certaines conditions de stabilité).
    • Impression : lance une impression.
    • Tester : touche analogique, fonction de pesage.
  • Touches de menu/navigation :
    • Menu Setup : appeler le menu Setup.
    • Exit : fermer et quitter le menu actuel.
    • OK : confirmer la saisie ou la sélection.
    • Curseur vers la gauche / droite / haut / bas : navigation dans les menus, sélection de paramètres et modification des chiffres.
L T

John L.

Is it normal for the display to show 0.1 kg after zeroing?

D'après le document, il est tout à fait possible que l'afficheur indique une valeur telle que 0,1 kg (ou un faible écart) après une mise à zéro. En effet, la fonction de mise à zéro possède une étendue de tolérance appelée étendue de mise à zéro (paramètre ZESrnG) ainsi qu'une zone de vérification automatique qui permet de compenser de petits écarts (dans la limite de l'échelon et des paramètres de l'appareil).

Preparing document for printing…
0%