INSTALLATION MANUAL PRODUCT NAME : Maxi TUBE - Surface Downlight 1. 220-240V 50-60Hz Ordering Code 4003-7-5-506-XX 2. 4003-6/7/9-3-887-XX 3. 4003-7-3-891-XX 4. 4003-6-3-505-XX 5. 4003-7-3-902-XX 6. 4003-5/7-3-905-XX 7. 4003-7-3-877-XX 8. 4003-6/7/9-3-878-XX 9. 4003-7-3-873-XX + Input voltage - No. IP65 1-6 7-9 Light Emitting Diodes (LED) 1 3 Light Emitting Diodes (LED) 41 41 û175 48 262 24 4 2.2 2.3 Screw size ¢¹Ò´Ê¡ÃÙà¡ÅÕÂÇ»ÅÍ Wall plug anchor size ¢¹Ò´¾Ø¡½§¼¹Ñ§ L D L Ø7 mm./ÁÁ. 37 mm./ÁÁ. Ø7 mm./ÁÁ. D L D D 2 L Ø4mm./ÁÁ. 38mm./ÁÁ. 4.2 4.1 2.1 4.3 Last Revised On : 21/05/2024 REV.03 1/4 Bush protected against dripping water. ºÙª»Í§¡Ñ¹¹éíÒ«ÖÁà¢ÒµÑÇâ¤Á FR-DD-29 REV.00 EFF 11/03/24 5.1 For On-Off system. ÊíÒËÃѺÃкºà»´ - »´ Top-view 6 6.3 L 6.2 Torque/áçºÔ´ : 3.0 Nm. 6.6 N 6.1 5.2 For 1-10V dimming and DALI system. ÊíÒËÃѺÃкº´ÔÁ1-10V áÅÐÃкºDALI Green/Yellow (ÊÕà¢ÕÂÇ/ÊÕàËÅ×ͧ) : Brown (ÊÕ¹éíÒµÒÅ) : L Blue (ÊÕ¹éíÒà§Ô¹) : N A = 38-40 mm. B = 8-10 mm. White (ÊÕ¢ÒÇ) : + C = 30-32 mm. Black (ÊÕ´íÒ) : - 6.4 Top-view 6.5 A B C Cable Size/¢¹Ò´ÊÒÂä¿ : 5x1.00 mm.2 Ø 8-13 mm. 7 L + To Luminaire. /à¢Òâ¤Áä¿ 1...10V - N L N 2:1:+ DA2 DA1 For DALI system. ÊíÒËÃѺÃкºDALI Installation complete ¡ÒõԴµÑé§àÊÃç¨ÊÁºÙó Remark : ËÁÒÂà赯 1. Installation should be carried out by a qualified electrician in accordance with appropriate national wiring regulation. ¡ÒõԴµÑé§â¤Áä¿¿ÒáÅÐÍØ»¡Ã³ ¤ÇôíÒà¹Ô¹¡ÒÃâ´ÂªÒ§ä¿¿Ò ·ÕèÁÕ¤ÇÒÁÃÙáÅФÇÒÁªíÒ¹Ò­ 㹡ÒõԴµÑé§ÍØ»¡Ã³ä¿¿Ò â´Â੾ÒеÒÁÁÒµÃฐÒ¹¢Í§¡ÒÃä¿¿Ò 2. Disconnect the power before changing the lamp. »´ÊÇÔ·ªä¿·Ø¡¤ÃÑ駷Õèà»ÅÕè¹ËÅÍ´ä¿ 3. This is Class1 luminaire, the installation must be completed with earthing. â¤Áä¿Ãع¹Õ鶡٠¨Ñ´äÇã¹»ÃÐàÀ·¢Í§¡Òûͧ¡Ñ¹ä¿¿ÒÃÑèÇ ÃдѺ 1 ·Õè¨ÐµÍ§µÍÊÒ´ԹµÒÁÁÒµÃฐÒ¹¤ÇÒÁ»ÅÍ´ÀÑ 4. Do not exceed the maximum wattage. ËÒÁãªËÅÍ´ä¿·ÕèÁÕ¢¹Ò´Çѵµà¡Ô¹¡ÇÒ·ÕèÃÐºØ ËÃ×ÍãªËÅÍ´¼Ô´»ÃÐàÀ· 5. Don't touch LED while maintaining or cleaning. ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED ¢³ÐºíÒÃاÃÑ¡ÉÒ ËÃ×Í·íÒ¤ÇÒÁÊÐÍÒ´ Last Revised On : 21/05/2024 REV.03 2/4 FR-DD-29 REV.00 EFF 11/03/24 Warning : ¢Í¤ÇÃÃÐÇѧ 1. The manufacturer will not be liable or held responsible for any incorrect installation, misuse or improper use and unauthorised modification to the fittings. Failure to comply with mentioned warning may cause serious damage or serious injury to persons, animals or objects. If any modification is required please consult your dealer for the details. ·Ò§¼Ù¼ÅÔµäÁÊÒÁÒöÃѺ¼Ô´ªÍºã¹¤ÇÒÁàÊÕÂËÒÂã´æ·Õèà¡Ô´¨Ò¡¡ÒõԴµÑé§äÁ¶Ù¡ÇÔ¸,Õ ãª§Ò¹¼Ô´»ÃÐàÀ·ËÃ×Í´Ñ´á»Å§µÑÇâ¤Áã¹·Ø¡¡Ã³Õ «Öè§ ÊÔ觼Դ»¡µÔàËÅÒ¹Õé ÍÒ¨·íÒãËà¡Ô´ÍѹµÃÒ¡Ѻ ¤¹ ÊÑµÇ ÊÔ觢ͧ ËÒ¡ÁÕ¢ÍʧÊÑÂËÃ×ÍÁÕ¤ÇÒÁµÍ§¡ÒûÃѺᵧµÑÇâ¤Á ãËàËÁÒÐÊÁ¡Ñº¡ÒÃ㪧ҹ ¡ÃسҵԴµÍµÑÇá·¹¨íÒ˹ÒÂËÃ×ͼټÅÔµ 2. Where damage has occured to the fittings, please make the replacement with standard parts before use. 㹡óշèÁÕ ÕªÔé¹Êǹ»ÃСͺã´à¡Ô´¤ÇÒÁàÊÕÂËÒ¡ÃسÒà»ÅÕ蹪Թé ÊǹãËÁ¡Í ¹¡ÒÃ㪧ҹ·Ø¡¤ÃÑé§ à¾×èͤÇÒÁ»ÅÍ´ÀÑ For On-Off System. ÊíÒËÃѺ Ãкºà»´-»´ Cable Size/¢¹Ò´ÊÒÂä¿ : 3x1.00 mm.2 Ø8-13 mm. In case the supply cable is exposed to sunlight use UV resistant cable. ¡Ã³Õ·ÕèÁÕ¡ÒõԴµÑé§â¤Á俹͡ÍÒ¤Òà ËÃ×Íâ¤Áä¿·ÕèÁÕ¡ÒÃá¼ÃѧÊÕÂÙÇÕ ÊÒÂ俵ͧÊÒÁÒö»Í§¡Ñ¹ ËÃ×Í ÁÕ¡Òûͧ¡Ñ¹äÁã˶١ÃѧÊÕÂÙÇÕä´ NO Do not touch the LED because it may shorten the life time or the LED can be breaking down. ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED â´Âà´ç´¢Ò´ à¾ÃÒШзíÒãËËÅÍ´àÊ×èÍÁÊÀÒ¾ Minimum distance to lighted surface. ÃÐÂÐËÒ§¢Ñé¹µèíÒ ¨Ò¡Ë¹Òâ¤Á¶Ö§¾×é¹¼ÔÇ·Õ趡٠ÊͧÊÇÒ§ 0.5 m Any damaged safety glass cover must be replaced only with the original spare part. àÁ×èÍ¡ÃШ¡à¡Ô´¤ÇÒÁàÊÕÂËÒ à¾×èͤÇÒÁ»ÅÍ´ÀѤÇÃÊÑè§ÍÐäËÅá·¨Ò¡¼Ù¼ÅÔµà·Ò¹Ñé¹ Not using chemical compounds and aggressive agents such as , weed repellents fertilizers , acid solvent and contaminated irrigation water near the Luminaires. ËÒÁãªÊÒÃà¤ÁÕહ »ØÂ, ÂÒ¡íҨѴÈѵÃپת, »Ù¹¢ÒÇ, ÊÒÃÅÐÅÒ·Õè໹¡Ã´ áÅйéíÒ»¹à»Í¹ÊÒÃà¤ÁÕ ºÃÔàdz·ÕèµÔ´µÑé§â¤Áä¿ NO NO Last Revised On : 21/05/2024 REV.03 Clean the products regularly to maintain good light output and prolong surface quality . Only use solvent-free cleaning solutions on the products. ·íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ±à»¹»ÃШíÒà¾×èÍÃÑ¡ÉÒ¤ÇÒÁÊͧÊÇÒ§·Õè´ÕáÅÐÂ×´ÍÒÂؤسÀÒ¾¾×é¹¼ÔÇ ãª¹éíÒÂÒ·íÒ¤ÇÒÁÊÐÍÒ´·ÕèäÁÁÕáÍÅ¡ÍÎÍÅËÃ×͵ÑÇ·íÒÅÐÅÒ¡Ѻ¼ÅÔµÀѳ±à·Ò¹Ñé¹ 3/4 FR-DD-29 REV.00 EFF 11/03/24 NO Do not use a high pressure washer to clean the products. ËÒÁãªà¤Ã×èͧ©Õ´¹éíÒáç´Ñ¹Ê٧㹡Ò÷íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ± Our products are installed with electronic components with the protection against overvoltage according to IEC 61547. The customers have to install the additional overvoltage protection devices (against surge, transients, etc) in their electrical system to avoid the risk of damage. Failing to do so will end the product warranty. ¼ÅÔµÀѳ±¢Í§àÃÒÁÕ¡ÒõԴµÑé§ÍØ»¡Ã³ÍÔàÅç¡·Ã͹ԡÊÊíÒËÃѺ¡Òûͧ¡Ñ¹áç´Ñ¹ä¿à¡Ô¹µÒÁÁÒµÃฐÒ¹ IEC 61547 áÅÐÅÙ¡¤ÒµÍ§µÔ´µÑé§ÍØ»¡Ã³»Í§¡Ñ¹áç´Ñ¹ä¿à¡Ô¹à¾ÔèÁàµÔÁ (»Í§¡Ñ¹ä¿¡ÃЪҡ ,ä¿¿ÒÅѴǧ¨Ã ÏÅÏ)ã¹Ãкºä¿¿Ò´Ç à¾×èÍËÅÕ¡àÅÕ觤ÇÒÁàÊÕ觷Õè¨Ðà¡Ô´¤ÇÒÁàÊÕÂËÒ ËÒ¡äÁ´íÒà¹Ô¹¡Òôѧ¡ÅÒÇ ¡ÒÃÃѺ»ÃСѹ¨ÐÊÔé¹Êشŧ LED LED LED To replace the LED module or the entrire luminaire.Please consult your sales representative. ËÒ¡µÍ§¡ÒÃà»ÅÕè¹ LED module ËÃ×Íâ¤Áä¿â»Ã´µÔ´µÍµÑÇá·¹¢Ò¢ͧ¤Ø³ LED 230 V Environmental protection: Waste electrical products should not be disposed of with household waste. please recycle where facilities exist.check with your local authority or retailer for recycling advice According to directive 2002/96/CE and directive 2012/19/EU Waste Electrical and Electronic Equipment (WEEE). ËÒÁ·Ô駼ÅÔµÀѳ±¹éÃÕ ÇÁ¡Ñº¢ÂÐ㹤ÃÑÇàÃ×͹ª¹Ô´Í×è¹æàÁ×èÍÊÔé¹ÊØ´ÍÒÂØ¡ÒÃ㪧ҹâ»Ã´á¡¼ÅÔµÀѳ±ÍÍ¡ ¨Ò¡¢Í§àÊÕ»ÃÐàÀ·Í×è¹æáÅÐÃÕä«à¤ÔÅÍÂÒ§àËÁÒÐÊÁà¾×èÍʧàÊÃÔÁ¡ÒùíÒ·ÃѾÂҡáÅѺÁÒ㪫íÒé «Ö觨ЪÇ »Í§¡Ñ¹ÍѹµÃÒµÍÊÔè§áÇ´ÅÍÁËÃ×ÍÊØ¢ÀÒ¾¢Í§Á¹ØÉ·Õèà¡Ô´¨Ò¡¡Ò÷Ô駢ÂÐâ´ÂäÁÁ¡Õ ÒäǺ¤ØÁ ÍÒ§ÍÔ§µÒÁÃÐàºÕº 2002/96/CE áÅÐÃÐàºÕº 2012/19/EU Waste Electrical and Electronic Equipment (WEEE). Replacing the LED module ÇÔ¸Õ¡ÒÃà»ÅÕè¹ LED module 1. Contact your sales representative for replacement LED modules. Make sure that the replacement module match the initially supplied module. Note the part number printed on the LED module. àµÃÕÂÁ LED module ã˵ç¡ÑºÃع·ÕèµÍ§¡ÒÃà»ÅÕè¹â´ÂµÃǨÊͺ·ÕèËÁÒÂàÅ¢·Õè¾ÔÁ¾º¹LED modules áÅÐ µÔ´µÍµÑÇá·¹¢ÒÂà¾×èÍÊÑ觫×éÍ LED modules ·ÕèµÍ§¡ÒÃà»ÅÕè¹ 2. The LED module can be replaced by qualified persons using standard tools. ¡ÒÃà»ÅÕè¹ LED module µÍ§·íÒâ´ÂªÒ§¼ÙªíÒ¹Ò­áÅÐãªà¤Ã×èͧÁ×Í·Õèä´ÁÒµÃฐÒ¹ 3. Disconnect power before opening the luminaire housing. µÑ´áËŧ¨ÒÂ信͹·Õè¨Ðà»´µÑÇâ¤Á 4. Replace the old LED module with the new LED module. Reapply thermal interface material as supplied with the new LED module. ¶Í´ LED module ·ÕèªíÒÃØ´ÍÍ¡ ¨Ò¡¹Ñ¹·íÒ¤ÇÒÁÊÐÍÒ´¨Ø´ÇÒ§ËÅÍ´ áÅǨ֧·íÒ¡ÒûÃСͺ LED module ãËÁ áÅеͧà»ÅÕè¹ á¼¹Thermal Pad ËÃ×Í Thermal Grease ´Ç·ء¤ÃÑé§ 5. Inspect gaskets and if required replace with new gaskets. Defective luminaire covers must be replaced. Inspect correct wiring of replaced LED module. µÃǨÊͺ»ÃÐà¡ç¹áÅЪÔé¹Êǹ¢Í§µÑÇâ¤Á ¶ÒªíÒÃØ´àÊÕÂËÒÂãË·íÒ¡ÒÃà»ÅÕè¹ãËÁ áÅеÃǨÊͺ¡ÒÃà¢ÒÊÒÂ俢ͧ LED module ·Õèà»ÅÕè¹ãËÁ¶Ù¡µÍ§ËÃ×ÍäÁ 6. Close the luminaire housing before reconnecting power. »´½Ò¤ÃͺÅçͤâ¤Áä¿ãËàÃÕºÃÍÂ¡Í¹à»´ä¿ Last Revised On : 21/05/2024 REV.03 4/4 FR-DD-29 REV.00 EFF 11/03/24 ">

Öffentlicher Link aktualisiert
Der öffentliche Link zu Ihrem Chat wurde aktualisiert.