Unilamp SIRIUS 1200 - CV Mode d'emploi
PDF
Scarica
Documento
INSTALLATION MANUAL PRODUCT NAME : SIRIUS(600,1200,300) - CV/CC Ceiling Mount SIRIUS(600 HI,1200 HI) - CC Ceiling Mount IP67 Input No. 1. lll Ordering Code 4231/4232-A/B/C/K/H-3-554-XX 220-240V~50/60Hz 2. 4231/4232-A/B/C/K/H-3-555/556-XX 3. 4231/4232/4233-A/B/C/K/H-3-474/475/476-XX 4. 4231/4232/4233-A/B/C/K/H-3-548/549/550-XX 5. 4231/4232/4233-A/B/C/K/H-4-548/549/550-XX 6. 4231/4232/4233-A/B/C/K/H-5-548/549/550-XX 7. 4231-C/E/K-3-542-XX 4231-C/E/K-3-543-XX 9. 4232-C/E/K-3/4/5-542-XX 1-16 10. 4232-C/E/K-3/4/5-543-XX 11. 4231-C/E/K-3/4/5-540/541-XX Light Emitting Diode (LED) 12. 4232-C/E/K-3-540/541-XX 13. 4231-A/B/C/H/K-3/4/5-695/696/697-XX 14. 4232-A/B/C/H/K-3/4/5-695/696/697-XX 4233-A/B/C/H/K-3/5-695/696/697-XX 16. (CV) Constant Voltage - remote driver / 24V input 4231/4232/4233-A/B/C/K/H-2-551/552/553-XX Model Item ÃËÑÊÊÔ¹¤Ò ÅíҴѺ 1 OD-4231 2 OD-4232 3 OD-4233 68 95 Size/¢¹Ò´ A A 62 2 Wall plug anchor size ¢¹Ò´¾Ø¡½§¼¹Ñ§ D 1 L Model Item ÅíҴѺ ÃËÑÊÊÔ¹¤Ò 1 OD-4231 2 OD-4232 3 OD-4233 600 1180 310 Do not cut or disconnect the cable between this area. ËÒÁµÑ´µÍÊÒÂ俺ÃÔàdz¹Õé D 2.2 Screw size ¢¹Ò´Ê¡ÃÙà¡ÅÕÂÇ»ÅÍ H Ø 4 mm. Ø9 mm. L 38 mm. B B 340 800 150 D L Size/¢¹Ò´ Ø7 mm./ÁÁ. 2.1 3 L Ø7 mm./ÁÁ. 37 mm./ÁÁ. D 15. H 8. 80 Wall bracket ỹÂÖ´¼¹Ñ§ Use appropriate installation material depending on installation conditions. àÅ×Í¡Ê¡ÃÙáÅÐÍØ»¡Ã³ÂÖ´¨Ñº·ÕèàËÁÒÐÊÁ ¡Ñº¾×é¹·Õè áÅлÃÐàÀ·¡ÒõԴµÑé§ 4 3.2 3.1 For on-off and remote driver. ÊíÒËÃѺÃкºà»´-»´ áÅÐÃÕâÁ· ä´ÃàÇÍà IP68 water tight connecting device 3 Pole. Cable Diameter 5.0-9.5mm. Available Separately/ªØ´¢ÍµÍÊÒÂ信ѹ¹éíÒIP68, ÊíÒËÃѺÊÒÂä¿ 3ÊÒ ¨íÒ˹ÒÂᡵҧËÒ¡ Ordering Code : AUN-CON-0009-00 See connecting detail manual. ´ÙÃÒÂÅÐàÍÕ´·Õè¤ÙÁ×Í¡ÒõԴµÑé§ Last Revised On : 23/04/2024 REV.08 Installation complete µÔ´µÑé§àÊÃç¨ÊÁºÙó 1/6 FR-DD-29 REV.00 EFF 11/03/24 For Constant Voltage LED 24V Luminaires 1-n (SIRIUS 600 - CV Ceiling Mount ) Warning: Luminaire must be operated with remote driver that is conform to SELV ¢Í¤ÇÃÃÐÇѧ:áç´Ñ¹ä¿¿Ò·Õè¨ÒÂà¢ÒµÑÇâ¤Á¨Ò¡ ÃÕâÁ·ä´ÃàÇÍÃÀÒ¹͡µÍ§à»¹ä¿¿Òáç´Ñ¹µèíÒ¾ÔàÈÉ L à·Ò¹Ñé¹ Input/à¢Ò 220-240 V~ AC N + + 1 - + 2 - + n - - DC Output/ÍÍ¡ 24 V ( Output from SELV system only) (¡ÃÐáÊ俵ͧÁÒ¨Ò¡Ãкºáç´Ñ¹ä¿¿Ò µèíÒ¾ÔàÈÉ¢Ñé¹»ÅÍ´ÀÑÂà¾Õ§à·Ò¹Ñé¹) Distance from luminaire to Driver ÃÐÂзҧ¨Ò¡µÑÇâ¤Á¶Ö§ ä´ÃàÇÍà Conductor size / ¢¹Ò´ÊÒÂä¿ Maximum number of luminaires Connected fixtures/ for parallel connection / â¤Á·ÕèµÔ´µÑé§ Accessory available separately./ÍØ»¡Ã³àÊÃÔÁ¨íÒ˹ÒÂᡵҧËÒ¡ Ordering Code Product Name ¨íҹǹâ¤Á㹡ÒõÍẺ¢¹Ò¹ AUN-DRG-0027-00 LED Constant Voltage Driver 24Vdc 72W. AUN-DRG-0011-00 LED Constant Voltage Driver 24Vdc 150W. 1-3 luminaires/â¤Á 1-6 luminaires/â¤Á 1.00 mm2 1.50 mm2 2.00 mm2 1 luminaire/â¤Á 150 m 220 m 300 m 2 luminaires/â¤Á 70 m 110 m 150 m 3 luminaire/â¤Á 20 m 30 m 40 m 1 luminaire/â¤Á 150 m 220 m 300 m 2 luminaires/â¤Á 70 m 110 m 150 m 3 luminaires/â¤Á 40 m 60 m 85 m 4 luminaires/â¤Á 30 m 45 m 60 m 5 luminaires/â¤Á 25 m 35 m 50 m 6 luminaires/â¤Á 5m 10 m 15 m For Constant Voltage LED 24Vdc Luminaires 1-n (SIRIUS 1200 - CV Ceiling Mount ) Warning: Luminaire must be operated with remote driver that is conform to SELV ¢Í¤ÇÃÃÐÇѧ:áç´Ñ¹ä¿¿Ò·Õè¨ÒÂà¢ÒµÑÇâ¤Á¨Ò¡ ÃÕâÁ·ä´ÃàÇÍÃÀÒ¹͡µÍ§à»¹ä¿¿Òáç´Ñ¹µèíÒ¾ÔàÈÉ L à·Ò¹Ñé¹ Input/à¢Ò 220-240 V~ AC N + + 1 - + 2 - + n - - DC Output/ÍÍ¡ 24 V ( Output from SELV system only) (¡ÃÐáÊ俵ͧÁÒ¨Ò¡Ãкºáç´Ñ¹ä¿¿Ò µèíÒ¾ÔàÈÉ¢Ñé¹»ÅÍ´ÀÑÂà¾Õ§à·Ò¹Ñé¹) Distance from luminaire to Driver ÃÐÂзҧ¨Ò¡µÑÇâ¤Á¶Ö§ ä´ÃàÇÍà Conductor size / ¢¹Ò´ÊÒÂä¿ Maximum number of luminaires Connected fixtures/ for parallel connection / â¤Á·ÕèµÔ´µÑé§ Accessory available separately./ÍØ»¡Ã³àÊÃÔÁ¨íÒ˹ÒÂᡵҧËÒ¡ Ordering Code Product Name ¨íҹǹâ¤Á㹡ÒõÍẺ¢¹Ò¹ 1.00 mm2 1.50 mm2 2.00 mm2 AUN-DRG-0027-00 LED Constant Voltage Driver 24Vdc 72W. 1 luminaire/â¤Á 1 luminaire/â¤Á 75 m 110 m 150 m AUN-DRG-0011-00 LED Constant Voltage Driver 24Vdc 150W. 1-3 luminaires/â¤Á 1 luminaire/â¤Á 75 m 110 m 140 m 2 luminaires/â¤Á 35 m 55 m 75 m 3 luminaires/â¤Á 10 m 20 m 25 m Last Revised On : 23/04/2024 REV.08 2/6 FR-DD-29 REV.00 EFF 11/03/24 For Constant Voltage LED 24Vdc Luminaires 1-n (SIRIUS 300 - CV Ceiling Mount ) Warning: Luminaire must be operated with remote driver that is conform to SELV ¢Í¤ÇÃÃÐÇѧ:áç´Ñ¹ä¿¿Ò·Õè¨ÒÂà¢ÒµÑÇâ¤Á¨Ò¡ ÃÕâÁ·ä´ÃàÇÍÃÀÒ¹͡µÍ§à»¹ä¿¿Òáç´Ñ¹µèíÒ¾ÔàÈÉ L à·Ò¹Ñé¹ Input/à¢Ò 220-240 V~ AC N + DC + 1 - + 2 - + n - - Output/ÍÍ¡ 24 V ( Output from SELV system only) (¡ÃÐáÊ俵ͧÁÒ¨Ò¡Ãкºáç´Ñ¹ä¿¿Ò µèíÒ¾ÔàÈÉ¢Ñé¹»ÅÍ´ÀÑÂà¾Õ§à·Ò¹Ñé¹) Distance from luminaire to Driver ÃÐÂзҧ¨Ò¡µÑÇâ¤Á¶Ö§ ä´ÃàÇÍà Conductor size / ¢¹Ò´ÊÒÂä¿ Maximum number of luminaires Connected fixtures/ for parallel connection / â¤Á·ÕèµÔ´µÑé§ Accessory available separately./ÍØ»¡Ã³àÊÃÔÁ¨íÒ˹ÒÂᡵҧËÒ¡ Ordering Code Product Name ¨íҹǹâ¤Á㹡ÒõÍẺ¢¹Ò¹ AUN-DRG-0027-00 LED Constant Voltage Driver 24Vdc 72W 1-6 luminaires/â¤Á AUN-DRG-0011-00 LED Constant Voltage Driver 24Vdc 150W. 1-6 luminaires/â¤Á 1.00 mm2 1.50 mm2 2.00 mm2 1 luminaire/â¤Á 300 m 450 m 500 m 2 luminaires/â¤Á 150 m 225 m 300 m 3 luminaires/â¤Á 100 m 150 m 200 m 4 luminaires/â¤Á 75 m 114 m 152 m 5 luminaires/â¤Á 61 m 90 m 122 m 6 luminaires/â¤Á 20 m 31 m 41 m 1 luminaire/â¤Á 150 m 220 m 300 m 2 luminaires/â¤Á 70 m 110 m 150 m 3 luminaires/â¤Á 40 m 60 m 85 m 4 luminaires/â¤Á 30 m 45 m 60 m 5 luminaires/â¤Á 25 m 35 m 50 m 6 luminaires/â¤Á 5m 10 m 15 m For 1-10V dimming and DALI system. ÊíÒËÃѺÃкº´ÔÁ1-10V áÅÐÃкºDALI A B A = 38-40 mm. B = 8-10 mm. C = 30-32 mm. Green/Yellow : Brown :L Blue :N White : + /DA1 Black : - /DA2 C Cable Size/¢¹Ò´ÊÒÂä¿ : 5x1.00 mm.2 Ø7.1-13 mm. IP68 water tight connecting device 5 Pole.Cable Diameter 7.1-13mm. Available Separately/ªØ´¢ÍµÍÊÒÂ信ѹ¹éíÒIP68, ÊíÒËÃѺÊÒÂä¿ 5 ÊҠᡨíÒ˹ÒµҧËÒ¡ Ordering Code : AUN-CON-0011-00 Last Revised On : 23/04/2024 REV.08 3/6 FR-DD-29 REV.00 EFF 11/03/24 Remark : ËÁÒÂà赯 1. Installation should be carried out by a qualified electrician in accordance with appropriate national wiring regulation. ¡ÒõԴµÑé§â¤Áä¿¿ÒáÅÐÍØ»¡Ã³ ¤ÇôíÒà¹Ô¹¡ÒÃâ´ÂªÒ§ä¿¿Ò ·ÕèÁÕ¤ÇÒÁÃÙáÅФÇÒÁªíÒ¹Ò­ 㹡ÒõԴµÑé§ÍØ»¡Ã³ä¿¿Ò â´Â੾ÒеÒÁÁÒµÃฐÒ¹¢Í§¡ÒÃä¿¿Ò 2. Disconnect the power before changing the lamp. »´ÊÇÔ·ªä¿·Ø¡¤ÃÑ駷Õèà»ÅÕè¹ËÅÍ´ä¿ 3. For Class1 luminaire, the installation must be completed with earthing. ÊíÒËÃѺâ¤Áä¿·ÕèÁ¡Õ Òûͧ¡Ñ¹ä¿¿ÒÃÑèÇÃдѺ1 ¡ÒõԴµÑ駵ͧµÍÊÒ´ԹµÒÁÁÒµÃฐÒ¹¤ÇÒÁ»ÅÍ´ÀÑ´Ç 4. Do not exceed the maximum wattage. ËÒÁãªËÅÍ´ä¿·ÕèÁÕ¢¹Ò´Çѵµà¡Ô¹¡ÇÒ·ÕèÃÐºØ ËÃ×ÍãªËÅÍ´¼Ô´»ÃÐàÀ· 5. Don't touch LED while maintaining or cleaning. ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED ¢³ÐºíÒÃاÃÑ¡ÉÒ ËÃ×Í·íÒ¤ÇÒÁÊÐÍÒ´ Warning : ¢Í¤ÇÃÃÐÇѧ 1. The manufacturer will not be liable or held responsible for any incorrect installation, misuse or improper use and unauthorised modification to the fittings. Failure to comply with mentioned warning may cause serious damage or serious injury to persons, animals or objects. If any modification is required please consult your dealer for the details. ·Ò§¼Ù¼ÅÔµäÁÊÒÁÒöÃѺ¼Ô´ªÍºã¹¤ÇÒÁàÊÕÂËÒÂã´æ·Õèà¡Ô´¨Ò¡ ¡ÒõԴµÑé§äÁ¶Ù¡ÇÔ¸Õ,㪧ҹ¼Ô´»ÃÐàÀ·ËÃ×Í´Ñ´á»Å§µÑÇâ¤Áã¹·Ø¡¡Ã³Õ «Öè§ÊÔ觼Դ»¡µÔàËÅÒ¹Õé ÍÒ¨·íÒãËà¡Ô´ÍѹµÃÒ¡Ѻ ¤¹ ÊÑµÇ ÊÔ觢ͧ ËÒ¡ÁÕ¢ÍʧÊÑÂËÃ×ÍÁÕ¤ÇÒÁµÍ§¡ÒûÃѺᵧµÑÇâ¤Á ãËàËÁÒÐÊÁ¡Ñº¡ÒÃ㪧ҹ ¡ÃسҵԴµÍµÑÇá·¹¨íÒ˹ÒÂËÃ×ͼټÅÔµ 2. Where damage has occured to the fittings, please make the replacement with standard parts before use. 㹡óշèÁÕ Õªé¹Ô Êǹ»ÃСͺã´à¡Ô´¤ÇÒÁàÊÕÂËÒ¡ÃسÒà»ÅÕè¹ ªÔé¹ÊǹãËÁ¡Í ¹¡ÒÃ㪧ҹ·Ø¡¤ÃÑé§ à¾×èͤÇÒÁ»ÅÍ´ÀÑ For class1 2 Cable Size/¢¹Ò´ÊÒÂä¿ : 3x1.00 mm. Ø5-9.5 mm. For class3 lll 2 Cable Size/¢¹Ò´ÊÒÂä¿ : 2x1.00 mm. Ø5-9.5 mm. In case the supply cable is exposed to sunlight use UV resistant cable. ¡Ã³Õ·ÕèÁÕ¡ÒõԴµÑé§â¤Á俹͡ÍÒ¤Òà ËÃ×Íâ¤Áä¿·ÕèÁÕ¡ÒÃá¼ÃѧÊÕÂÙÇÕ ÊÒÂ俵ͧÊÒÁÒö»Í§¡Ñ¹ ËÃ×Í ÁÕ¡Òûͧ¡Ñ¹äÁã˶١ÃѧÊÕÂÙÇÕä´ NO 0.5 m Do not touch the LED because it may shorten the life time or the LED can be breaking down. ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED â´Âà´ç´¢Ò´ à¾ÃÒШзíÒãËËÅÍ´àÊ×èÍÁÊÀÒ¾ Minimum distance to lighted surface. ÃÐÂÐËÒ§¢Ñé¹µèíÒ ¨Ò¡Ë¹Òâ¤Á¶Ö§¾×é¹¼ÔÇ·Õ趡٠ÊͧÊÇÒ§ The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 0.5m in not expected. µíÒá˹§·ÕèµÔ´µÑ駴ǧâ¤Á¤ÇÃÍÂÙ㹨ش·ÕèáʧäÁÊͧà¢Ò´Ç§µÒâ´ÂµÃ§à»¹àÇÅÒ¹Ò¹ ËÒ¡à¢Òã¡Åã¹ ÃÐÂйÍ¡ÇÒ 0.5 Á. Any damaged safety glass cover must be replaced only with the original spare part. àÁ×èÍ¡ÃШ¡à¡Ô´¤ÇÒÁàÊÕÂËÒ à¾×èͤÇÒÁ»ÅÍ´ÀѤÇÃÊÑè§ÍÐäËÅá·¨Ò¡¼Ù¼ÅÔµà·Ò¹Ñé¹ Last Revised On : 23/04/2024 REV.08 4/6 FR-DD-29 REV.00 EFF 11/03/24 Our products are installed with electronic components with the protection against overvoltage according to IEC 61547. The customers have to install the additional overvoltage protection devices (against surge, transients, etc) in their electrical system to avoid the risk of damage. Failing to do so will end the product warranty. ¼ÅÔµÀѳ±¢Í§àÃÒÁÕ¡ÒõԴµÑé§ÍØ»¡Ã³ÍÔàÅç¡·Ã͹ԡÊÊíÒËÃѺ¡Òûͧ¡Ñ¹áç´Ñ¹ä¿à¡Ô¹µÒÁÁÒµÃฐÒ¹ IEC 61547 áÅÐÅÙ¡¤ÒµÍ§µÔ´µÑé§ÍØ»¡Ã³»Í§¡Ñ¹áç´Ñ¹ä¿à¡Ô¹à¾ÔèÁàµÔÁ (»Í§¡Ñ¹ä¿¡ÃЪҡ ,ä¿¿ÒÅѴǧ¨Ã ÏÅÏ)ã¹Ãкºä¿¿Ò´Ç à¾×èÍËÅÕ¡àÅÕ觤ÇÒÁàÊÕ觷Õè¨Ðà¡Ô´¤ÇÒÁàÊÕÂËÒ ËÒ¡äÁ´íÒà¹Ô¹¡Òôѧ¡ÅÒÇ ¡ÒÃÃѺ»ÃСѹ¨ÐÊÔé¹Êشŧ LED NO NO For class1 LED LED Clean the products regularly to maintain good light output and prolong surface quality . Only use solvent-free cleaning solutions on the products. ·íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ±à»¹»ÃШíÒà¾×èÍÃÑ¡ÉÒ¤ÇÒÁÊͧÊÇÒ§·Õè´ÕáÅÐÂ×´ÍÒÂؤسÀÒ¾¾×é¹¼ÔÇ ãª¹éíÒÂÒ·íÒ¤ÇÒÁÊÐÍÒ´·ÕèäÁÁÕáÍÅ¡ÍÎÍÅËÃ×͵ÑÇ·íÒÅÐÅÒ¡Ѻ¼ÅÔµÀѳ±à·Ò¹Ñé¹ Do not use a high pressure washer to clean the products. ËÒÁãªà¤Ã×èͧ©Õ´¹éíÒáç´Ñ¹Ê٧㹡Ò÷íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ± To replace the LED module or the entrire luminaire.Please consult your sales representative. ËÒ¡µÍ§¡ÒÃà»ÅÕè¹ LED module ËÃ×Íâ¤Áä¿â»Ã´µÔ´µÍµÑÇá·¹¢Ò¢ͧ¤Ø³ LED 230V For class3 LED LED To replace the LED module or the entrire luminaire.Please consult your sales representative. ËÒ¡µÍ§¡ÒÃà»ÅÕè¹ LED module ËÃ×Íâ¤Áä¿â»Ã´µÔ´µÍµÑÇá·¹¢Ò¢ͧ¤Ø³ Environmental protection: Waste electrical products should not be disposed of with household waste. please recycle where facilities exist.check with your local authority or retailer for recycling advice According to directive 2002/96/CE and directive 2012/19/EU Waste Electrical and Electronic Equipment (WEEE). ËÒÁ·Ô駼ÅÔµÀѳ±¹éÃÕ ÇÁ¡Ñº¢ÂÐ㹤ÃÑÇàÃ×͹ª¹Ô´Í×è¹æàÁ×èÍÊÔé¹ÊØ´ÍÒÂØ¡ÒÃ㪧ҹâ»Ã´á¡¼ÅÔµÀѳ±ÍÍ¡ ¨Ò¡¢Í§àÊÕ»ÃÐàÀ·Í×è¹æáÅÐÃÕä«à¤ÔÅÍÂÒ§àËÁÒÐÊÁà¾×èÍʧàÊÃÔÁ¡ÒùíÒ·ÃѾÂҡáÅѺÁÒ㪫éíÒ«Ö觨ЪÇ »Í§¡Ñ¹ÍѹµÃÒµÍÊÔè§áÇ´ÅÍÁËÃ×ÍÊØ¢ÀÒ¾¢Í§Á¹ØÉ·Õèà¡Ô´¨Ò¡¡Ò÷Ô駢ÂÐâ´ÂäÁÁ¡Õ ÒäǺ¤ØÁ ÍÒ§ÍÔ§µÒÁÃÐàºÕº 2002/96/CE áÅÐÃÐàºÕº 2012/19/EU Waste Electrical and Electronic Equipment (WEEE). Last Revised On : 23/04/2024 REV.08 5/6 FR-DD-29 REV.00 EFF 11/03/24 Replacing the LED module ÇÔ¸Õ¡ÒÃà»ÅÕè¹ LED module 1. Contact your sales representative for replacement LED modules. Make sure that the replacement module match the initially supplied module. Note the part number printed on the LED module. àµÃÕÂÁ LED module ã˵ç¡ÑºÃع·ÕèµÍ§¡ÒÃà»ÅÕè¹â´ÂµÃǨÊͺ·ÕèËÁÒÂàÅ¢·Õè¾ÔÁ¾º¹LED modules áÅÐ µÔ´µÍµÑÇá·¹¢ÒÂà¾×èÍÊÑ觫×éÍ LED modules ·ÕèµÍ§¡ÒÃà»ÅÕè¹ 2. The LED module can be replaced by qualified persons using standard tools. ¡ÒÃà»ÅÕè¹ LED module µÍ§·íÒâ´ÂªÒ§¼ÙªíÒ¹Ò­áÅÐãªà¤Ã×èͧÁ×Í·Õèä´ÁÒµÃฐÒ¹ 3. Disconnect power before opening the luminaire housing. µÑ´áËŧ¨ÒÂ信͹·Õè¨Ðà»´µÑÇâ¤Á 4. Replace the old LED module with the new LED module. Reapply thermal interface material as supplied with the new LED module. ¶Í´ LED module ·ÕèªíÒÃØ´ÍÍ¡ ¨Ò¡¹Ñ¹·íÒ¤ÇÒÁÊÐÍÒ´¨Ø´ÇÒ§ËÅÍ´ áÅǨ֧·íÒ¡ÒûÃСͺ LED module ãËÁ áÅеͧà»ÅÕè¹ á¼¹Thermal Pad ËÃ×Í Thermal Grease ´Ç·ء¤ÃÑé§ 5. Inspect gaskets and if required replace with new gaskets. Defective luminaire covers must be replaced. Inspect correct wiring of replaced LED module. µÃǨÊͺ»ÃÐà¡ç¹áÅЪÔé¹Êǹ¢Í§µÑÇâ¤Á ¶ÒªíÒÃØ´àÊÕÂËÒÂãË·íÒ¡ÒÃà»ÅÕè¹ãËÁ áÅеÃǨÊͺ¡ÒÃà¢ÒÊÒÂ俢ͧ LED module ·Õèà»ÅÕè¹ãËÁ¶Ù¡µÍ§ËÃ×ÍäÁ 6. Close the luminaire housing before reconnecting power. »´½Ò¤ÃͺÅçͤâ¤Áä¿ãËàÃÕºÃÍÂ¡Í¹à»´ä¿ Last Revised On : 23/04/2024 REV.08 6/6 FR-DD-29 REV.00 EFF 11/03/24 ">

Link pubblico aggiornato
Il link pubblico alla tua chat è stato aggiornato.