Unilamp SIRIUS 300 - CV Mode d'emploi
PDF
Descarregar
Documento
INSTALLATION MANUAL PRODUCT NAME : SIRIUS 300 - CV Wall Washer SIRIUS 300 - CC Wall Washer IP67 Input Ordering Code 1. 220-240V~50/60Hz 8033-A/B/C/K/H-3/4/5-548/549/550-XX 2. 8033-A/B/C/K/H-3-695/696/697/474/475/476-XX 3. 8033-A/B/C/K/H-5-695/696/697-XX 4. (CV) Constant Voltage - remote driver / 24V input ( Output from SELV system only) 5. ( ¡ÃÐáÊ俵ͧÁÒ¨Ò¡Ãкºáç´Ñ¹ä¿¿Ò µèíÒ¾ÔàÈÉ¢Ñé¹»ÅÍ´ÀÑÂà¾Õ§à·Ò¹Ñé¹) 6. 8033-A/B/C/K/H-2-551-XX 1-6 8033-A/B/C/K/H-2-553-XX Light Emitting Diode (LED) 62 D L L Ø7 mm./ÁÁ. 37 mm./ÁÁ. D L 2.2 2.1 Screw size ¢¹Ò´Ê¡ÃÙà¡ÅÕÂÇ»ÅÍ H Ø 4 mm. Ø9 mm. L 38 mm. 130 Use appropriate installation material depending on installation conditions. àÅ×Í¡Ê¡ÃÙáÅÐÍØ»¡Ã³ÂÖ´¨Ñº·ÕèàËÁÒÐÊÁ ¡Ñº¾×é¹·Õè áÅлÃÐàÀ·¡ÒõԴµÑé§ 122 Do not cut or disconnect the cable between this area. ËÒÁµÑ´µÍÊÒÂ俺ÃÔàdz¹Õé Wall plug anchor size ¢¹Ò´¾Ø¡½§¼¹Ñ§ Ø7 mm./ÁÁ. 310 2 D 62 D 1 8033-A/B/C/K/H-2-552-XX H No. lll Wall bracket ỹÂÖ´¼¹Ñ§ 2.3 Torque/áçºÔ´ : 1.0 Nm. 4 3 3.2 For on-off and remote driver. ÊíÒËÃѺÃкºà»´-»´ áÅÐÃÕâÁ· ä´ÃàÇÍà IP68 water tight connecting device 3 Pole.Cable Diameter 5.0-9.5mm. Available Separately/ªØ´¢ÍµÍÊÒÂ信ѹ¹éíÒIP68, ÊíÒËÃѺÊÒÂä¿ 3ÊÒ ¨íÒ˹ÒÂᡵҧËÒ¡ Ordering Code : AUN-CON-0009-00 See connecting detail manual. ´ÙÃÒÂÅÐàÍÕ´·Õè¤ÙÁ×Í¡ÒõԴµÑé§ 6 25 3.1 Torque/áçºÔ´ : 1.0 Nm. Last Revised On : 23/04/2024 REV.06 6 30 2 Cable size : 3x1.00 mm. Ø5-9.5mm. ¢¹Ò´ÊÒÂä¿ Installation complete µÔ´µÑé§àÊÃç¨ÊÁºÙó 1/5 FR-DD-30 REV.00 EFF 11/03/2024 For Constant Voltage LED 24Vdc Warning: Luminaire must be operated with remote driver that is conform to SELV ¢Í¤ÇÃÃÐÇѧ:áç´Ñ¹ä¿¿Ò·Õè¨ÒÂà¢ÒµÑÇâ¤Á¨Ò¡ ÃÕâÁ·ä´ÃàÇÍÃÀÒ¹͡µÍ§à»¹ä¿¿Òáç´Ñ¹µèíÒ¾ÔàÈÉ à·Ò¹Ñé¹ L AC Input/à¢Ò 220-240 V~ N DC Luminaires 1-n + + 1 - + 2 - + n - - Output/ÍÍ¡ 24 V ( Output from SELV system only) (¡ÃÐáÊ俵ͧÁÒ¨Ò¡Ãкºáç´Ñ¹ä¿¿Ò µèíÒ¾ÔàÈÉ¢Ñé¹»ÅÍ´ÀÑÂà¾Õ§à·Ò¹Ñé¹) Parallel wiring constant voltage Distance from luminaire to Driver Accessory available separately./ÍØ»¡Ã³àÊÃÔÁ¨íÒ˹ÒÂᡵҧËÒ¡ ÃÐÂзҧ¨Ò¡µÑÇâ¤Á¶Ö§ ä´ÃàÇÍà Ordering Code Product Name Conductor size / ¢¹Ò´ÊÒÂä¿ Maximum number of luminaires Connected fixtures/ for parallel connection / â¤Á·ÕèµÔ´µÑé§ ¨íҹǹâ¤Á㹡ÒõÍẺ¢¹Ò¹ AUN-DRG-0027-00 LED Constant Voltage Driver 24Vdc 72W 1-6 luminaires/â¤Á AUN-DRG-0011-00 LED Constant Voltage Driver 24Vdc 150W. 1-6 luminaires/â¤Á 1.00 mm2 1.50 mm2 2.00 mm2 1 luminaire/â¤Á 300 m 450 m 500 m 2 luminaires/â¤Á 150 m 225 m 300 m 3 luminaires/â¤Á 100 m 150 m 200 m 4 luminaires/â¤Á 75 m 114 m 152 m 5 luminaires/â¤Á 61 m 90 m 122 m 6 luminaires/â¤Á 20 m 31 m 41 m 1 luminaire/â¤Á 300 m 450 m 500 m 2 luminaires/â¤Á 150 m 225 m 300 m 3 luminaires/â¤Á 100 m 150 m 200 m 4 luminaires/â¤Á 75 m 110 m 150 m 5 luminaires/â¤Á 60 m 90 m 120 m 6 luminaires/â¤Á 50 m 75 m 100 m For 1-10V dimming and DALI system. ÊíÒËÃѺÃкº´ÔÁ1-10V áÅÐÃкºDALI A B A = 38-40 mm. B = 8-10 mm. C = 30-32 mm. Green/Yellow : Brown :L Blue :N White : + /DA1 Black : - /DA2 C Cable Size/¢¹Ò´ÊÒÂä¿ : 5x1.00 mm.2 Ø7.1-13 mm. IP68 water tight connecting device 5 Pole.Cable Diameter 7.1-13mm. Available Separately/ªØ´¢ÍµÍÊÒÂ信ѹ¹éíÒIP68, ÊíÒËÃѺÊÒÂä¿ 5 ÊҠᡨíÒ˹ÒµҧËÒ¡ Ordering Code : AUN-CON-0011-00 Last Revised On : 23/04/2024 REV.06 2/5 FR-DD-30 REV.00 EFF 11/03/2024 Remark : ËÁÒÂà赯 1. Installation should be carried out by a qualified electrician in accordance with appropriate national wiring regulation. ¡ÒõԴµÑé§â¤Áä¿¿ÒáÅÐÍØ»¡Ã³ ¤ÇôíÒà¹Ô¹¡ÒÃâ´ÂªÒ§ä¿¿Ò ·ÕèÁÕ¤ÇÒÁÃÙáÅФÇÒÁªíÒ¹Ò­ 㹡ÒõԴµÑé§ÍØ»¡Ã³ä¿¿Ò â´Â੾ÒеÒÁÁÒµÃฐÒ¹¢Í§¡ÒÃä¿¿Ò 2. Disconnect the power before changing the lamp. »´ÊÇÔ·ªä¿·Ø¡¤ÃÑ駷Õèà»ÅÕè¹ËÅÍ´ä¿ 3. For Class1 luminaire, the installation must be completed with earthing. ÊíÒËÃѺâ¤Áä¿·ÕèÁ¡Õ Òûͧ¡Ñ¹ä¿¿ÒÃÑèÇÃдѺ1 ¡ÒõԴµÑ駵ͧµÍÊÒ´ԹµÒÁÁÒµÃฐÒ¹¤ÇÒÁ»ÅÍ´ÀÑ´Ç 4. Do not exceed the maximum wattage. ËÒÁãªËÅÍ´ä¿·ÕèÁÕ¢¹Ò´Çѵµà¡Ô¹¡ÇÒ·ÕèÃÐºØ ËÃ×ÍãªËÅÍ´¼Ô´»ÃÐàÀ· 5. Don't touch LED while maintaining or cleaning. ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED ¢³ÐºíÒÃاÃÑ¡ÉÒ ËÃ×Í·íÒ¤ÇÒÁÊÐÍÒ´ Warning : ¢Í¤ÇÃÃÐÇѧ 1. The manufacturer will not be liable or held responsible for any incorrect installation, misuse or improper use and unauthorised modification to the fittings. Failure to comply with mentioned warning may cause serious damage or serious injury to persons, animals or objects. If any modification is required please consult your dealer for the details. ·Ò§¼Ù¼ÅÔµäÁÊÒÁÒöÃѺ¼Ô´ªÍºã¹¤ÇÒÁàÊÕÂËÒÂã´æ·Õèà¡Ô´¨Ò¡ ¡ÒõԴµÑé§äÁ¶Ù¡ÇÔ¸Õ,㪧ҹ¼Ô´»ÃÐàÀ·ËÃ×Í´Ñ´á»Å§µÑÇâ¤Áã¹·Ø¡¡Ã³Õ «Öè§ÊÔ觼Դ»¡µÔàËÅÒ¹Õé ÍÒ¨·íÒãËà¡Ô´ÍѹµÃÒ¡Ѻ ¤¹ ÊÑµÇ ÊÔ觢ͧ ËÒ¡ÁÕ¢ÍʧÊÑÂËÃ×ÍÁÕ¤ÇÒÁµÍ§¡ÒûÃѺᵧµÑÇâ¤Á ãËàËÁÒÐÊÁ¡Ñº¡ÒÃ㪧ҹ ¡ÃسҵԴµÍµÑÇá·¹¨íÒ˹ÒÂËÃ×ͼټÅÔµ 2. Where damage has occured to the fittings, please make the replacement with standard parts before use. 㹡óշÕèÁÕªé¹Ô Êǹ»ÃСͺã´à¡Ô´¤ÇÒÁàÊÕÂËÒ¡ÃسÒà»ÅÕè¹ ªÔé¹ÊǹãËÁ¡Í ¹¡ÒÃ㪧ҹ·Ø¡¤ÃÑé§ à¾×èͤÇÒÁ»ÅÍ´ÀÑ For class1 2 Cable Size/¢¹Ò´ÊÒÂä¿ : 3x1.00 mm. Ø5-9.5 mm. For class3 lll 2 Cable Size/¢¹Ò´ÊÒÂä¿ : 2x1.00 mm. Ø5-9.5 mm. In case the supply cable is exposed to sunlight use UV resistant cable. ¡Ã³Õ·ÕèÁÕ¡ÒõԴµÑé§â¤Á俹͡ÍÒ¤Òà ËÃ×Íâ¤Áä¿·ÕèÁÕ¡ÒÃá¼ÃѧÊÕÂÙÇÕ ÊÒÂ俵ͧÊÒÁÒö»Í§¡Ñ¹ ËÃ×Í ÁÕ¡Òûͧ¡Ñ¹äÁã˶١ÃѧÊÕÂÙÇÕä´ NO 0.5 m Do not touch the LED because it may shorten the life time or the LED can be breaking down. ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED â´Âà´ç´¢Ò´ à¾ÃÒШзíÒãËËÅÍ´àÊ×èÍÁÊÀÒ¾ Minimum distance to lighted surface. ÃÐÂÐËÒ§¢Ñé¹µèíÒ ¨Ò¡Ë¹Òâ¤Á¶Ö§¾×é¹¼ÔÇ·Õ趡٠ÊͧÊÇÒ§ The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 0.5m in not expected. µíÒá˹§·ÕèµÔ´µÑ駴ǧâ¤Á¤ÇÃÍÂÙ㹨ش·ÕèáʧäÁÊͧà¢Ò´Ç§µÒâ´ÂµÃ§à»¹àÇÅÒ¹Ò¹ ËÒ¡à¢Òã¡Åã¹ ÃÐÂйÍ¡ÇÒ 0.5 Á. Any damaged safety glass cover must be replaced only with the original spare part. àÁ×èÍ¡ÃШ¡à¡Ô´¤ÇÒÁàÊÕÂËÒ à¾×èͤÇÒÁ»ÅÍ´ÀѤÇÃÊÑè§ÍÐäËÅá·¨Ò¡¼Ù¼ÅÔµà·Ò¹Ñé¹ Last Revised On : 23/04/2024 REV.06 3/5 FR-DD-30 REV.00 EFF 11/03/2024 Not using chemical compounds and aggressive agents such as , weed repellents fertilizers , acid solvent and contaminated irrigation water near the Luminaires. ËÒÁãªÊÒÃà¤ÁÕહ »ØÂ, ÂÒ¡íҨѴÈѵÃپת, »Ù¹¢ÒÇ, ÊÒÃÅÐÅÒ·Õè໹¡Ã´ áÅйéíÒ»¹à»Í¹ÊÒÃà¤ÁÕ ºÃÔàdz·ÕèµÔ´µÑé§â¤Áä¿ No To reduce the risk of being constricted The wires attached to this lamp must be effectively fixed to the wall. if the power cord is within reach. à¾×èÍÅ´¤ÇÒÁàÊÕ觵͡Òö١ÊÒÂä¿à¡ÕèÂÇ/ÃÑ´ ÊÒÂä¿·ÕèµÍà¢ÒµÑÇâ¤ÁµÍ§¶Ù¡µÔ´ÂÖ´¡Ñº¼¹Ñ§ÍÂÒ§àÃÕºÃÍ Cable Cable Our products are installed with electronic components with the protection against overvoltage according to IEC 61547. The customers have to install the additional overvoltage protection devices (against surge, transients, etc) in their electrical system to avoid the risk of damage. Failing to do so will end the product warranty. ¼ÅÔµÀѳ±¢Í§àÃÒÁÕ¡ÒõԴµÑé§ÍØ»¡Ã³ÍÔàÅç¡·Ã͹ԡÊÊíÒËÃѺ¡Òûͧ¡Ñ¹áç´Ñ¹ä¿à¡Ô¹µÒÁÁÒµÃฐÒ¹ IEC 61547 áÅÐÅÙ¡¤ÒµÍ§µÔ´µÑé§ÍØ»¡Ã³»Í§¡Ñ¹áç´Ñ¹ä¿à¡Ô¹à¾ÔèÁàµÔÁ (»Í§¡Ñ¹ä¿¡ÃЪҡ ,ä¿¿ÒÅѴǧ¨Ã ÏÅÏ)ã¹Ãкºä¿¿Ò´Ç à¾×èÍËÅÕ¡àÅÕ觤ÇÒÁàÊÕ觷Õè¨Ðà¡Ô´¤ÇÒÁàÊÕÂËÒ ËÒ¡äÁ´íÒà¹Ô¹¡Òôѧ¡ÅÒÇ ¡ÒÃÃѺ»ÃСѹ¨ÐÊÔé¹Êشŧ LED NO NO For class1 LED LED Clean the products regularly to maintain good light output and prolong surface quality . Only use solvent-free cleaning solutions on the products. ·íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ±à»¹»ÃШíÒà¾×èÍÃÑ¡ÉÒ¤ÇÒÁÊͧÊÇÒ§·Õè´ÕáÅÐÂ×´ÍÒÂؤسÀÒ¾¾×é¹¼ÔÇ ãª¹éíÒÂÒ·íÒ¤ÇÒÁÊÐÍÒ´·ÕèäÁÁÕáÍÅ¡ÍÎÍÅËÃ×͵ÑÇ·íÒÅÐÅÒ¡Ѻ¼ÅÔµÀѳ±à·Ò¹Ñé¹ Do not use a high pressure washer to clean the products. ËÒÁãªà¤Ã×èͧ©Õ´¹éíÒáç´Ñ¹Ê٧㹡Ò÷íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ± To replace the LED module or the entrire luminaire.Please consult your sales representative. ËÒ¡µÍ§¡ÒÃà»ÅÕè¹ LED module ËÃ×Íâ¤Áä¿â»Ã´µÔ´µÍµÑÇá·¹¢Ò¢ͧ¤Ø³ LED 230V Last Revised On : 23/04/2024 REV.06 4/5 FR-DD-30 REV.00 EFF 11/03/2024 For class3 LED LED To replace the LED module or the entrire luminaire.Please consult your sales representative. ËÒ¡µÍ§¡ÒÃà»ÅÕè¹ LED module ËÃ×Íâ¤Áä¿â»Ã´µÔ´µÍµÑÇá·¹¢Ò¢ͧ¤Ø³ Environmental protection: Waste electrical products should not be disposed of with household waste. please recycle where facilities exist.check with your local authority or retailer for recycling advice According to directive 2002/96/CE and directive 2012/19/EU Waste Electrical and Electronic Equipment (WEEE). ËÒÁ·Ô駼ÅÔµÀѳ±¹éÃÕ ÇÁ¡Ñº¢ÂÐ㹤ÃÑÇàÃ×͹ª¹Ô´Í×è¹æàÁ×èÍÊÔé¹ÊØ´ÍÒÂØ¡ÒÃ㪧ҹâ»Ã´á¡¼ÅÔµÀѳ±ÍÍ¡ ¨Ò¡¢Í§àÊÕ»ÃÐàÀ·Í×è¹æáÅÐÃÕä«à¤ÔÅÍÂÒ§àËÁÒÐÊÁà¾×èÍʧàÊÃÔÁ¡ÒùíÒ·ÃѾÂҡáÅѺÁÒ㪫íÒé «Ö觨ЪÇ »Í§¡Ñ¹ÍѹµÃÒµÍÊÔè§áÇ´ÅÍÁËÃ×ÍÊØ¢ÀÒ¾¢Í§Á¹ØÉ·Õèà¡Ô´¨Ò¡¡Ò÷Ô駢ÂÐâ´ÂäÁÁ¡Õ ÒäǺ¤ØÁ ÍÒ§ÍÔ§µÒÁÃÐàºÕº 2002/96/CE áÅÐÃÐàºÕº 2012/19/EU Waste Electrical and Electronic Equipment (WEEE). Replacing the LED module ÇÔ¸Õ¡ÒÃà»ÅÕè¹ LED module 1. Contact your sales representative for replacement LED modules. Make sure that the replacement module match the initially supplied module. Note the part number printed on the LED module. àµÃÕÂÁ LED module ã˵ç¡ÑºÃع·ÕèµÍ§¡ÒÃà»ÅÕè¹â´ÂµÃǨÊͺ·ÕèËÁÒÂàÅ¢·Õè¾ÔÁ¾º¹LED modules áÅÐ µÔ´µÍµÑÇá·¹¢ÒÂà¾×èÍÊÑ觫×éÍ LED modules ·ÕèµÍ§¡ÒÃà»ÅÕè¹ 2. The LED module can be replaced by qualified persons using standard tools. ¡ÒÃà»ÅÕè¹ LED module µÍ§·íÒâ´ÂªÒ§¼ÙªíÒ¹Ò­áÅÐãªà¤Ã×èͧÁ×Í·Õèä´ÁÒµÃฐÒ¹ 3. Disconnect power before opening the luminaire housing. µÑ´áËŧ¨ÒÂ信͹·Õè¨Ðà»´µÑÇâ¤Á 4. Replace the old LED module with the new LED module. Reapply thermal interface material as supplied with the new LED module. ¶Í´ LED module ·ÕèªíÒÃØ´ÍÍ¡ ¨Ò¡¹Ñ¹·íÒ¤ÇÒÁÊÐÍÒ´¨Ø´ÇÒ§ËÅÍ´ áÅǨ֧·íÒ¡ÒûÃСͺ LED module ãËÁ áÅеͧà»ÅÕè¹ á¼¹Thermal Pad ËÃ×Í Thermal Grease ´Ç·ء¤ÃÑé§ 5. Inspect gaskets and if required replace with new gaskets. Defective luminaire covers must be replaced. Inspect correct wiring of replaced LED module. µÃǨÊͺ»ÃÐà¡ç¹áÅЪÔé¹Êǹ¢Í§µÑÇâ¤Á ¶ÒªíÒÃØ´àÊÕÂËÒÂãË·íÒ¡ÒÃà»ÅÕè¹ãËÁ áÅеÃǨÊͺ¡ÒÃà¢ÒÊÒÂ俢ͧ LED module ·Õèà»ÅÕè¹ãËÁ¶Ù¡µÍ§ËÃ×ÍäÁ 6. Close the luminaire housing before reconnecting power. »´½Ò¤ÃͺÅçͤâ¤Áä¿ãËàÃÕºÃÍÂ¡Í¹à»´ä¿ Last Revised On : 23/04/2024 REV.06 5/5 FR-DD-30 REV.00 EFF 11/03/2024 ">

Link público atualizado
O link público para o seu chat foi atualizado.