Unilamp SIRIUS 1200 Mode d'emploi
PDF
Descargar
Documento
INSTALLATION MANUAL PRODUCT NAME : SIRIUS 1200/HI - CC Ground Recess : SIRIUS 1200 - CV Ground Recess lll IP67 Ordering Code Glass Temperature At Ta 25°C 1. 220-240V~50/60Hz 9067-A/B/C/K/H-3-554/474/475/476-01 32 2. 9067-A/B/C/K/H-3-555-01 32 3. 9067-A/B/C/K/H-3-556-01 32 4. 9067-A/B/C/K/H-3/4/5-548-01 32.5 5. 9067-A/B/C/K/H-3/4/5-549-01 32.5 6. 9067-A/B/C/K/H-3/4/5-550-01 32.5 7. 9067-C/E/K-3/4/5-542/543-01 32.5 8. 9067-A/B/C/K/H-3/4/5-695/696/697-01 36.5 9. 9067-C/E/K-3-540-01 36.5 10. 9067-C/E/K-3-541-01 36.5 11. (CV) Constant Voltage - remote driver / 24VDC 9067-A/B/C/K/H-2-551-01 35.5 12. 9067-A/B/C/K/H-2-552-01 35.5 13. 9067-A/B/C/K/H-2-553-01 35.5 Input No. 1 1-13 Light Emitting Diode (LED) 2 2.1 2.2 Recess Housing Available separately/¡Åͧ½§¾×é¹ á¡¨íÒ˹Ò Ordering Code/ÃËÑÊÊÑ觫×éÍ : AUN-RCH-0010-01 138 66 1190 Last Revised On : 23/04/2024 REV.07 93 1/6 Do not cut or disconnect the cable between this area. ËÒÁµÑ´µÍÊÒÂ俺ÃÔàdz¹Õé FR-DD-29 REV.00 EFF11/03/24 3 6 25 6 30 2 Cable size : 3X1.00 mm. Ø 5-9.5mm. ¢¹Ò´ÊÒÂä¿ 1230 3.1 4 Please note the ground level. ¢Í¤ÇÃÃÐÇѧ: ¼ÔÇ˹Ңͧ µÑÇâ¤Á¡Ñº¼ÔǾ×鹤ÇÃÍÂÙã¹ ÃйҺà´ÕÂǡѹ 135 Cable/ÊÒÂä¿ 138 Cable pipe ·ÍÊÒÂä¿ gravel ¡Í¹¡ÃÇ´ Water drainage pipe ·Í¹éíÒ·Ôé§ Take out steel supporter when concrete completely cured. ¶Í´µÑǤéíÒ¡ÅͧàËÅ硽§¾×é¹ÍÍ¡ àÁ×èͤ͹¡ÃÕµá¢ç§µÑÇ 3.2 4.2 Concrete/¤Í¹¡ÃÕµ 4.1 0° For on-off and remote driver./ÊíÒËÃѺÃкºà»´-»´ áÅÐÃÕâÁ· ä´ÃàÇÍà IP68 water tight connecting device 3 Pole. Cable Diameter 5.0-9.5mm. Available Separately/ªØ´¢ÍµÍÊÒÂ信ѹ¹éíÒIP68, ÊíÒËÃѺÊÒÂä¿ 3ÊÒ ¨íÒ˹ÒÂᡵҧËÒ¡ Ordering Code : AUN-CON-0009-00 See connecting detail manual./´ÙÃÒÂÅÐàÍÕ´·Õè¤ÙÁ×Í¡ÒõԴµÑé§ 5 Installation complete ¡ÒõԴµÑé§àÊÃç¨ÊÁºÙó For Constant Voltage LED 24Vdc (CV) Luminaires 1-n Warning: Luminaire must be operated with remote driver that is conform to SELV Input 220-240 Vac L AC N DC + + - 1 - + 2 - + n - Distance from luminaire to Driver/transformer ÃÐÂзҧ¨Ò¡µÑÇâ¤Á¶Ö§ ä´ÃàÇÍà /ËÁÍá»Å§ Maximum number of luminaires Connected fixtures/ Conductor size / ¢¹Ò´ÊÒÂä¿ for parallel connection / â¤Á·ÕèµÔ´µÑé§ Accessory available separately./ÍØ»¡Ã³àÊÃÔÁ¨íÒ˹ÒÂᡵҧËÒ¡ Ordering Code Product Name ¨íҹǹâ¤Á㹡ÒõÍẺ¢¹Ò¹ AUN-DRG-0011-00 LED Constant Voltage Driver 24Vdc 150W. Last Revised On : 23/04/2024 REV.07 1-3 luminaires/â¤Á 1.00 mm2 1.50 mm2 2.00 mm2 1 luminaire/â¤Á 25 m 40 m 55 m 2 luminaires/â¤Á 13 m 20 m 25 m 3 luminaires/â¤Á 9m 13 m 18 m 2/6 FR-DD-29 REV.00 EFF11/03/24 For 1-10V dimming and DALI system. ÊíÒËÃѺÃкº´ÔÁ1-10VáÅÐÃкºDALI A = 38-40 mm. B = 8-10 mm. C = 30-32 mm. Cable Size/¢¹Ò´ÊÒÂä¿ : 5x1.00 mm.2 Ø7.1 -13 mm. C A B Green/Yellow (ÊÕà¢ÕÂÇ/ÊÕàËÅ×ͧ) : Brown (ÊÕ¹éíÒµÒÅ) : L Blue (ÊÕ¹éíÒà§Ô¹) : N White (ÊÕ¢ÒÇ) : + Black (ÊÕ´íÒ) : - IP68 water tight connecting device 5 Pole.Cable Diameter 7.1-13mm. Available Separately/ªØ´¢ÍµÍÊÒÂ信ѹ¹éíÒIP68, ÊíÒËÃѺÊÒÂä¿ 5 ÊÒ ¨íÒ˹ÒÂᡵҧËÒ¡ Ordering Code : AUN-CON-0011-00 Remark : ËÁÒÂà赯 1. Installation should be carried out by a qualified electrician in accordance with appropriate national wiring regulation. ¡ÒõԴµÑé§â¤Áä¿¿ÒáÅÐÍØ»¡Ã³ ¤ÇôíÒà¹Ô¹¡ÒÃâ´ÂªÒ§ä¿¿Ò ·ÕèÁ¤Õ ÇÒÁÃÙáÅФÇÒÁªíÒ¹Ò­ 㹡ÒõԴµÑé§ÍØ»¡Ã³ä¿¿Ò â´Â੾ÒеÒÁÁÒµÃฐÒ¹¢Í§¡ÒÃä¿¿Ò 2. Disconnect the power before changing the lamp. »´ÊÇÔ·ªä¿·Ø¡¤ÃÑ駷Õèà»ÅÕè¹ËÅÍ´ä¿ 3. For Class1 luminaire, the installation must be completed with earthing. ÊíÒËÃѺâ¤Áä¿·ÕèÁÕ¡Òûͧ¡Ñ¹ä¿¿ÒÃÑèÇÃдѺ1 ¡ÒõԴµÑ駵ͧµÍÊÒ´ԹµÒÁÁÒµÃฐÒ¹¤ÇÒÁ»ÅÍ´ÀÑ´Ç 4. Do not exceed the maximum wattage. ËÒÁãªËÅÍ´ä¿·ÕèÁÕ¢¹Ò´Çѵµà¡Ô¹¡ÇÒ·ÕèÃÐºØ ËÃ×ÍãªËÅÍ´¼Ô´»ÃÐàÀ· 5. Don't touch LED while maintaining or cleaning. ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED ¢³ÐºíÒÃاÃÑ¡ÉÒ ËÃ×Í·íÒ¤ÇÒÁÊÐÍÒ´ Pic-1 ÃÙ»-1 20-30 cm. Cable pipe ·ÍÊÒÂä¿ Pic-2 ÃÙ»-2 Warning : ¢Í¤ÇÃÃÐÇѧ 1. The manufacturer will not be liable or held responsible for any incorrect installation, misuse or improper use and unauthorised modification to the fittings. Failure to comply with mentioned warning may cause serious damage or serious injury to persons, animals or objects. If any modification is required please consult your dealer for the details. ·Ò§¼Ù¼ÅÔµäÁÊÒÁÒöÃѺ¼Ô´ªÍºã¹¤ÇÒÁàÊÕÂËÒÂã´æ·Õèà¡Ô´¨Ò¡¡Òà µÔ´µÑé§äÁ¶¡Ù ÇÔ¸Õ, 㪧ҹ¼Ô´»ÃÐàÀ·ËÃ×Í´Ñ´á»Å§µÑÇâ¤Áã¹·Ø¡¡Ã³Õ «Öè§ ÊÔ觼Դ»¡µÔàËÅÒ¹Õé ÍÒ¨·íÒãËà¡Ô´ÍѹµÃÒ¡Ѻ ¤¹ ÊÑµÇ ÊÔ觢ͧ ËÒ¡ÁÕ¢ÍʧÊÑÂËÃ×ÍÁÕ¤ÇÒÁµÍ§¡ÒûÃѺᵧµÑÇâ¤Á ãËàËÁÒÐÊÁ¡Ñº¡ÒÃ㪧ҹ ¡ÃسҵԴµÍµÑÇá·¹¨íÒ˹ÒÂËÃ×ͼټÅÔµ 2. Where damage has occured to the fittings, please make the replacement with standard parts before use. 㹡óշÕèÁÕªé¹Ô Êǹ»ÃСͺã´à¡Ô´¤ÇÒÁàÊÕÂËÒ¡ÃسÒà»ÅÕ蹪Ôé¹ ÊǹãËÁ¡Í¹¡ÒÃ㪧ҹ·Ø¡¤ÃÑé§ à¾×èͤÇÒÁ»ÅÍ´ÀÑ General installation guide ( highly recommended) ¢Íá¹Ð¹íÒ㹡ÒõԴµÑé§ Place the gravel 20-30 cm.depth underneath the casing for water drainage (Pic-1).Then do the testing by filling water into the casing and let it drain.The water should be drained out by 30 minutes. If not,the additional drainage pipe or other system must be applied (Pic-2) ¤ÇÃÇÒ§¡Í¹¡ÃǴ㵡Åͧ½§¾×é¹·ÕèÃÐÂÐÅÖ¡»ÃÐÁÒ³ 20-30 «Á. à¾×èͪÇÂÃкÒ ¹éíÒ·Õè·ÇÁ¢Ñ§µÑÇâ¤Áä¿ ÊÒÁÒö·´Êͺ¡ÒÃÃкÒ¹éíÒâ´Âà·¹éíÒãÊ¡ÅͧãËàµçÁ ¹éíҨеͧÃкÒÂÍÍ¡ËÁ´ÀÒÂã¹àÇÅÒ 30¹Ò·Õ ËÒ¡äÁ໹µÒÁ¹Ñ鹤ÇÃÁÕ¡ÒÃµÍ ·ÍÃкÒ¹éíÒà¾ÔèÁàµÔÁ Water drainage pipe ·Í¹éíÒ·Ôé§ Last Revised On : 23/04/2024 REV.07 3/6 FR-DD-29 REV.00 EFF11/03/24 Installation should not be done under high humidity enviroment i.e. rainy day or after the rain,foggy weather....ect. äÁ¤ÇõԴµÑé§â¤Áä¿ã¹ªÇ§·ÕèÁÕ¤ÇÒÁª×é¹Ê٧હ Çѹ·Õè½¹µ¡µÅÍ´ËÃ×͵ԴµÑé§ËÅѧ ½¹ËÂØ´µ¡à¾ÃÒШзíÒãˤÇÒÁª×鹶١¢Ñ§äÇã¹µÑÇâ¤Áä¿ËÅѧ¨Ò¡¹Ñ鹨Ðà¡Ô´¡Òà ¤Çºá¹¹à»¹ÅÐÍͧËÃ×ÍË´¹éíÒà¡ÒеԴºÃÔàdz㵡ÃШ¡ÀÒÂã¹µÑÇâ¤Áä¿ Do not let the exposed part of the fittings be covered by the soil,dried weed or foliage as well as corrosive or aggressive substancechemicals. ÍÂÒ»ÅÍÂãËÁÕÊÔè§Ê¡»Ã¡àª¹ àÈÉ´Ô¹ ãºäÁ ËÃ×Í Ë­Òá˧ÃÇÁ¶Ö§à¤ÁÕ·Õè໹ÊÒÃ-¡Ñ´¡Ã͹ÁÒ»¡¤ÅØÁÊÐÊÁºÃÔàdz˹Ҿ×é¹¼ÔǵÑÇâ¤Áä¿ Do not throw or drop any hard objects onto the top of fittings. ÍÂÒãËÇѵ¶Ø·Õè໹¢Í§á¢ç§ËŹ ËÃ×͵¡¡ÃÐá·¡ãʺÃÔàdz˹Ҿ×é¹¼ÔǢͧµÑÇâ¤Á The surface temperature of the fitting can be very high after continuation in service. àÁ×èÍà»´ä¿·Ôé§äÇã¹ÃÐÂÐàÇÅÒ˹Ö觨Ðà¡Ô´¤ÇÒÁÃ͹ÊÐÊÁºÃÔàdz´Ò¹º¹¢Í§µÑÇâ¤Á俤ÇÃÃÐÁÑ´ÃÐÇѧ ¡ÒÃÊÑÁ¼Ñʶ١ºÃÔàdz´Ñ§¡ÅÒÇ Proper use of this fitting must be observed. ¤ÇþԨÒóҤÇÒÁàËÁÒÐÊÁ¢Í§¾×é¹·ÕèËÃ×͵íÒá˹§·Õè¨ÐµÔ´µÑ駵ÑÇâ¤Áä¿ µÑÇÍÂÒ§ હ ÁÕ ¹éíҢѧ໹»ÃШíÒ㹺ÃÔàdz¹Ñé¹ËÃ×ÍäÁ? , Çѵ¶ØµÒ§æ હ ´Ô¹,àÈÉãºäÁãºË­ÒÁÕâÍ¡ÒÈ·Õè¨ÐÁÒ»¡¤ÅØÁÊÐÊÁº¹Ë¹Òâ¤Á໹»ÃÔÁÒ³ÁÒ¡ËÃ×ÍäÁ? áÅÐäÁ¤ÇõԴµÑé§ã¹ºÃÔàdz·ÕèÍÒ¨ÁÕâÍ¡Òȶ١ÊÑÁ¼ÑÊâ´Â¤¹ â´Â੾ÒÐà´ç¡àÅç¡ËÃ×ÍÊѵÇàÅÕé§ Yes ¶Ù¡µÍ§ No äÁ¶Ù¡µÍ§ No äÁ¶Ù¡µÍ§ For class1 2 Cable Size/¢¹Ò´ÊÒÂä¿ : 3x1.00 mm. Ø5-9.5 mm. For class3 lll 2 Cable Size/¢¹Ò´ÊÒÂä¿ : 2x1.00 mm. Ø5-9.5 mm. In case the supply cable is exposed to sunlight use UV resistant cable. ¡Ã³Õ·ÕèÁÕ¡ÒõԴµÑé§â¤Á俹͡ÍÒ¤Òà ËÃ×Íâ¤Áä¿·ÕèÁÕ¡ÒÃá¼ÃѧÊÕÂÙÇÕ ÊÒÂ俵ͧÊÒÁÒö»Í§¡Ñ¹ ËÃ×Í ÁÕ¡Òûͧ¡Ñ¹äÁã˶١ÃѧÊÕÂÙÇÕä´ NO Last Revised On : 23/04/2024 REV.07 Do not touch the LED because it may shorten the life time or the LED can be breaking down. ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED â´Âà´ç´¢Ò´ à¾ÃÒШзíÒãËËÅÍ´àÊ×èÍÁÊÀÒ¾ 4/6 FR-DD-29 REV.00 EFF11/03/24 Minimum distance to lighted surface. ÃÐÂÐËÒ§¢Ñé¹µèíÒ ¨Ò¡Ë¹Òâ¤Á¶Ö§¾×é¹¼ÔÇ·Õ趡٠ÊͧÊÇÒ§ 0.5 m The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 0.5m in not expected. µíÒá˹§·ÕèµÔ´µÑ駴ǧâ¤Á¤ÇÃÍÂÙ㹨ش·ÕèáʧäÁÊͧà¢Ò´Ç§µÒâ´ÂµÃ§à»¹àÇÅÒ¹Ò¹ ËÒ¡à¢Òã¡Åã¹ ÃÐÂйÍ¡ÇÒ 0.5 Á. Any damaged safety glass cover must be replaced only with the original spare part. àÁ×èÍ¡ÃШ¡à¡Ô´¤ÇÒÁàÊÕÂËÒ à¾×èͤÇÒÁ»ÅÍ´ÀѤÇÃÊÑè§ÍÐäËÅá·¨Ò¡¼Ù¼ÅÔµà·Ò¹Ñé¹ No Not using chemical compounds and aggressive agents such as , weed repellents fertilizers , acid solvent and contaminated irrigation water near the Luminaires. ËÒÁãªÊÒÃà¤ÁÕહ »ØÂ, ÂÒ¡íҨѴÈѵÃپת, »Ù¹¢ÒÇ, ÊÒÃÅÐÅÒ·Õè໹¡Ã´ áÅйéíÒ»¹à»Í¹ÊÒÃà¤ÁÕ ºÃÔàdz·ÕèµÔ´µÑé§â¤Áä¿ Our products are installed with electronic components with the protection against overvoltage according to IEC 61547. The customers have to install the additional overvoltage protection devices (against surge, transients, etc) in their electrical system to avoid the risk of damage. Failing to do so will end the product warranty. ¼ÅÔµÀѳ±¢Í§àÃÒÁÕ¡ÒõԴµÑé§ÍØ»¡Ã³ÍÔàÅç¡·Ã͹ԡÊÊíÒËÃѺ¡Òûͧ¡Ñ¹áç´Ñ¹ä¿à¡Ô¹µÒÁÁÒµÃฐÒ¹ IEC 61547 áÅÐÅÙ¡¤ÒµÍ§µÔ´µÑé§ÍØ»¡Ã³»Í§¡Ñ¹áç´Ñ¹ä¿à¡Ô¹à¾ÔèÁàµÔÁ (»Í§¡Ñ¹ä¿¡ÃЪҡ ,ä¿¿ÒÅѴǧ¨Ã ÏÅÏ)ã¹Ãкºä¿¿Ò´Ç à¾×èÍËÅÕ¡àÅÕ觤ÇÒÁàÊÕ觷Õè¨Ðà¡Ô´¤ÇÒÁàÊÕÂËÒ ËÒ¡äÁ´íÒà¹Ô¹¡Òôѧ¡ÅÒÇ ¡ÒÃÃѺ»ÃСѹ¨ÐÊÔé¹Êشŧ LED NO NO For class1 LED LED Clean the products regularly to maintain good light output and prolong surface quality . Only use solvent-free cleaning solutions on the products. ·íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ±à»¹»ÃШíÒà¾×èÍÃÑ¡ÉÒ¤ÇÒÁÊͧÊÇÒ§·Õè´ÕáÅÐÂ×´ÍÒÂؤسÀÒ¾¾×é¹¼ÔÇ ãª¹éíÒÂÒ·íÒ¤ÇÒÁÊÐÍÒ´·ÕèäÁÁÕáÍÅ¡ÍÎÍÅËÃ×͵ÑÇ·íÒÅÐÅÒ¡Ѻ¼ÅÔµÀѳ±à·Ò¹Ñé¹ Do not use a high pressure washer to clean the products. ËÒÁãªà¤Ã×èͧ©Õ´¹éíÒáç´Ñ¹Ê٧㹡Ò÷íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ± To replace the LED module or the entrire luminaire.Please consult your sales representative. ËÒ¡µÍ§¡ÒÃà»ÅÕè¹ LED module ËÃ×Íâ¤Áä¿â»Ã´µÔ´µÍµÑÇá·¹¢Ò¢ͧ¤Ø³ LED 230 V Last Revised On : 23/04/2024 REV.07 5/6 FR-DD-29 REV.00 EFF11/03/24 For class3 LED LED To replace the LED module or the entrire luminaire.Please consult your sales representative. ËÒ¡µÍ§¡ÒÃà»ÅÕè¹ LED module ËÃ×Íâ¤Áä¿â»Ã´µÔ´µÍµÑÇá·¹¢Ò¢ͧ¤Ø³ Environmental protection: Waste electrical products should not be disposed of with household waste. please recycle where facilities exist.check with your local authority or retailer for recycling advice According to directive 2002/96/CE and directive 2012/19/EU Waste Electrical and Electronic Equipment (WEEE). ËÒÁ·Ô駼ÅÔµÀѳ±¹ÕéÃÇÁ¡Ñº¢ÂÐ㹤ÃÑÇàÃ×͹ª¹Ô´Í×è¹æàÁ×èÍÊÔé¹ÊØ´ÍÒÂØ¡ÒÃ㪧ҹâ»Ã´á¡¼ÅÔµÀѳ±ÍÍ¡ ¨Ò¡¢Í§àÊÕ»ÃÐàÀ·Í×è¹æáÅÐÃÕä«à¤ÔÅÍÂÒ§àËÁÒÐÊÁà¾×èÍʧàÊÃÔÁ¡ÒùíÒ·ÃѾÂҡáÅѺÁÒ㪫éíÒ«Ö觨ЪÇ »Í§¡Ñ¹ÍѹµÃÒµÍÊÔè§áÇ´ÅÍÁËÃ×ÍÊØ¢ÀÒ¾¢Í§Á¹ØÉ·Õèà¡Ô´¨Ò¡¡Ò÷Ô駢ÂÐâ´ÂäÁÁÕ¡ÒäǺ¤ØÁ ÍÒ§ÍÔ§µÒÁÃÐàºÕº 2002/96/CE áÅÐÃÐàºÕº 2012/19/EU Waste Electrical and Electronic Equipment (WEEE). Replacing the LED module ÇÔ¸Õ¡ÒÃà»ÅÕè¹ LED module 1. Contact your sales representative for replacement LED modules. Make sure that the replacement module match the initially supplied module. Note the part number printed on the LED module. àµÃÕÂÁ LED module ã˵ç¡ÑºÃع·ÕèµÍ§¡ÒÃà»ÅÕè¹â´ÂµÃǨÊͺ·ÕèËÁÒÂàÅ¢·Õè¾ÔÁ¾º¹LED modules áÅÐ µÔ´µÍµÑÇá·¹¢ÒÂà¾×èÍÊÑ觫×éÍ LED modules ·ÕèµÍ§¡ÒÃà»ÅÕè¹ 2. The LED module can be replaced by qualified persons using standard tools. ¡ÒÃà»ÅÕè¹ LED module µÍ§·íÒâ´ÂªÒ§¼ÙªíÒ¹Ò­áÅÐãªà¤Ã×èͧÁ×Í·Õèä´ÁÒµÃฐÒ¹ 3. Disconnect power before opening the luminaire housing. µÑ´áËŧ¨ÒÂ信͹·Õè¨Ðà»´µÑÇâ¤Á 4. Replace the old LED module with the new LED module. Reapply thermal interface material as supplied with the new LED module. ¶Í´ LED module ·ÕèªíÒÃØ´ÍÍ¡ ¨Ò¡¹Ñ¹·íÒ¤ÇÒÁÊÐÍÒ´¨Ø´ÇÒ§ËÅÍ´ áÅǨ֧·íÒ¡ÒûÃСͺ LED module ãËÁ áÅеͧà»ÅÕè¹ á¼¹Thermal Pad ËÃ×Í Thermal Grease ´Ç·ء¤ÃÑé§ 5. Inspect gaskets and if required replace with new gaskets. Defective luminaire covers must be replaced. Inspect correct wiring of replaced LED module. µÃǨÊͺ»ÃÐà¡ç¹áÅЪÔé¹Êǹ¢Í§µÑÇâ¤Á ¶ÒªíÒÃØ´àÊÕÂËÒÂãË·íÒ¡ÒÃà»ÅÕè¹ãËÁ áÅеÃǨÊͺ¡ÒÃà¢ÒÊÒÂ俢ͧ LED module ·Õèà»ÅÕè¹ãËÁ¶Ù¡µÍ§ËÃ×ÍäÁ 6. Close the luminaire housing before reconnecting power. »´½Ò¤ÃͺÅçͤâ¤Áä¿ãËàÃÕºÃÍÂ¡Í¹à»´ä¿ Last Revised On : 23/04/2024 REV.07 6/6 FR-DD-29 REV.00 EFF11/03/24 ">

Enlace público actualizado
El enlace público a tu chat ha sido actualizado.