Unilamp Medium TUBE - Down Mode d'emploi
PDF
Descarregar
Documento
INSTALLATION MANUAL PRODUCT NAME : Mini TUBE - Wall Downlight : Medium TUBE - Wall Downlight : Maxi TUBE - Wall Downlight IP65 Ordering Code 220-240V~50-60Hz 5004-5/6/7-3-901/904/503-XX 5004-5/6/7-4-901/904/503-XX 3. 5004-5/6/7-5-901/904/503-XX 4. 5005-5/6/7/9-3-902/905/505-XX 5. 5005-5/6/7/9-4-902/905/505-XX 6. 5005-5/6/7/9-5-902/905/505-XX 7. 5005-5/6/7/9-3-873/874-XX 8. 5005-A/C-3/4/5-534/535/536-XX 9. 5006-5/6/7/9-3/4/5-902-XX 10. 5006-5/6/7/9-3/4/5-905-XX 11. 5006-5/6/7/9-3/4/5-505-XX 12. 5006-5/6/7/9-3-887/891/506-XX 13. 5006-5/6/7/9-3-873/874-XX 14. 5006-5/6/7/9-3-877/878-XX 15. 5004-Q-3/4/5-630/644/645-XX 16. 5004-Q-3/4/5-646/647/648-XX + 2. 1 1-14 15-16 Light Emitting Diodes (LED) Light Emitting Diodes (LED) Wall plug anchor size ¢¹Ò´¾ÅØ ¡½§¼¹Ñ § D 2 D L D L Ø 7 mm./ÁÁ. 37 mm./ÁÁ. L H Ø 4 mm. Ø 9 mm. L 38 mm. 82 40 104 54 71 Screw size ¢¹Ò´Ê¡ÃÙ à¡ÅÕ ÂÇ»ÅÍ D 1. H Input voltage - No. D Wall bracket ỹÂÖ´¼¹Ñ§ OD-5005 Wall bracket ỹÂÖ´¼¹Ñ§ OD-5004 Wall bracket ỹÂÖ´¼¹Ñ§ OD-5006 Ø7mm./ÁÁ. C B 78 143 111 151 81 143 A 2.1 E Model Item ÃËÑÊÊÔ¹¤Ò ÅíҴѺ 1 OD-5004 LED 2 OD-5005 LED 3 OD-5006 LED Size/¢¹Ò´ A B C D 6 78 150 Ø105 199 174 112 160 Ø140 200 200 92 153 Ø175 269 248 Last Revised On : 20/10/2022 REV.09 25 2.2 E 6 30 2 Cable size : 3x1.00 mm. Ø 8-13 mm. ¢¹Ò´ÊÒÂä¿ 1/5 FR-DM-17 REV.03 EFF 15/09/17 3 4 3.1 Bush protected against dripping water. ºÙª»Í§¡Ñ¹¹éíÒ«ÖÁà¢ÒµÑÇ â¤Á 3.2 3.3 5 6 For 1-10V dimming and DALI system. ÊíÒËÃѺÃкº´ÔÁ1-10VáÅÐÃкºDALI Green/Yellow : Brown :L Blue :N White : + (DA1) Black : - (DA2) A = 38-40 mm. B = 8-10 mm. C = 30-32 mm. A B 5.3 C Cable Size/¢¹Ò´ÊÒÂä¿ : 5x1.00 mm.2 Ø8-13 mm. 5.2 - 1...10 V 5.1 L Torque/áçºÔ´ : 3 Nm. 5.4 1:+ DA2 2:- L L For DALI system. ÊíÒËÃѺÃкºDALI N Last Revised On : 20/10/2022 REV.09 DA1 N N + 2/5 FR-DM-17 REV.03 EFF 15/09/17 7 Installation complete ¡ÒõԴµÑé§àÊÃç¨ÊÁºÙó Remark : ËÁÒÂà赯 1. Installation should be carried out by a qualified electrician in accordance with appropriate national wiring regulation. ¡ÒõԴ µÑé§â¤Áä¿¿ÒáÅÐÍØ»¡Ã³ ¤ÇôíÒà¹Ô¹¡ÒÃâ´ÂªÒ§ä¿¿Ò ·ÕèÁÕ¤ÇÒÁÃÙáÅФÇÒÁªíÒ¹Ò­ 㹡ÒõԴ µÑé§ÍØ»¡Ã³ä¿¿Ò â´Â੾ÒеÒÁÁÒµÃฐÒ¹¢Í§¡ÒÃä¿¿Ò 2. Disconnect the power before changing the lamp. »´ÊÇÔ·ª ä¿·Ø¡¤ÃÑ駷Õèà»ÅÕè¹ËÅÍ´ä¿ 3. This is Class1 luminaire, the installation must be completed with earthing. â¤Áä¿Ãع¹Õé¶Ù¡¨Ñ´äÇã¹»ÃÐàÀ·¢Í§¡Òûͧ¡Ñ¹ä¿¿ÒÃÑèÇ ÃдѺ 1 ·Õè¨ÐµÍ§µÍÊÒ´ԹµÒÁÁÒµÃฐÒ¹¤ÇÒÁ»ÅÍ´ÀÑ Â 4. Do not exceed the maximum wattage. ËÒÁãªËÅÍ´ä¿·ÕèÁÕ¢¹Ò´Çѵµ à¡Ô¹¡ÇÒ·ÕèÃÐºØ ËÃ×ÍãªËÅÍ´¼Ô´»ÃÐàÀ· 5. Don't touch LED while maintaining or cleaning. ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED ¢³ÐºíÒÃاÃÑ¡ÉÒ ËÃ×Í·íÒ¤ÇÒÁÊÐÍÒ´ Warning : ¢Í¤ÇÃÃÐÇѧ 1. The manufacturer will not be liable or held responsible for any incorrect installation, misuse or improper use and unauthorised modification to the fittings. Failure to comply with mentioned warning may cause serious damage or serious injury to persons, animals or objects. If any modification is required please consult your dealer for the details. ·Ò§¼Ù¼ÅÔµäÁÊÒÁÒöÃѺ¼Ô´ªÍºã¹¤ÇÒÁàÊÕÂËÒÂã´æ·Õèà¡Ô´¨Ò¡¡ÒõԴµÑé§äÁ¶Ù¡ÇÔ¸Õ, 㪧ҹ¼Ô´»ÃÐàÀ·ËÃ×Í´Ñ´á»Å§µÑÇâ¤Áã¹·Ø¡¡Ã³Õ «Öè§ ÊÔ觼Դ»¡µÔàËÅÒ¹Õé ÍÒ¨·íÒãËà¡Ô´ÍѹµÃÒ¡Ѻ ¤¹ ÊÑµÇ ÊÔ觢ͧ ËÒ¡Á Õ¢ÍʧÊÑÂËÃ×ÍÁÕ¤ÇÒÁµÍ§¡ÒûÃѺᵧµÑÇâ¤Á ãËàËÁÒÐÊÁ¡Ñº¡ÒÃ㪧ҹ ¡Ãس ÒµÔ´µÍµÑÇá·¹¨íÒ˹ÒÂËÃ×ͼټÅÔµ 2. Where damage has occured to the fittings, please make the replacement with standard parts before use. 㹡óշÕèÁÕªÔé¹Êǹ»ÃСͺã´à¡Ô´¤ÇÒÁàÊÕÂËÒ¡Ãس Òà»ÅÕ蹪Ôé¹ÊǹãËÁ¡Í¹¡ÒÃ㪧ҹ·Ø¡¤ÃÑé§ à¾×èͤÇÒÁ»ÅÍ´ÀÑ For On-Off System. ÊíÒËÃѺÃкºà»´-»´ 2 Cable Size/¢¹Ò´ÊÒÂä¿ : 3x1.00 mm. Ø8-13 mm. In case the supply cable is exposed to sunlight use UV resistant cable. ¡Ã³Õ·ÕèÁÕ¡ÒõԴµÑé§â¤Á俹͡ÍÒ¤Òà ËÃ×Íâ¤Áä¿·ÕèÁÕ¡ÒÃá¼ÃѧÊÕÂÙÇÕ ÊÒÂ俵ͧÊÒÁÒö»Í§¡Ñ¹ ËÃ×Í ÁÕ¡Òûͧ¡Ñ¹äÁã˶١ÃѧÊÕÂÙÇÕä´ NO 0.5 m Last Revised On : 20/10/2022 REV.09 Do not touch the LED because it may shorten the life time or the LED can be breaking down. ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED â´Âà´ç´¢Ò´ à¾ÃÒШзíÒãËËÅÍ´àÊ×èÍÁÊÀÒ¾ Minimum distance to lighted surface. ÃÐÂÐËÒ§¢Ñé¹µèíÒ ¨Ò¡Ë¹Òâ¤Á¶Ö§¾×é¹¼ÔÇ·Õè¶Ù¡ÊͧÊÇÒ§ 3/5 FR-DM-17 REV.03 EFF 15/09/17 Any damaged safety glass cover must be replaced only with the original spare part. àÁ×èÍ¡ÃШ¡à¡Ô´¤ÇÒÁàÊÕÂËÒ à¾×èͤÇÒÁ»ÅÍ´ÀѤÇÃÊÑè§ÍÐäËÅá·¨Ò¡¼Ù¼ÅÔµà·Ò¹Ñé¹ Not using chemical compounds and aggressive agents such as , weed repellents fertilizers , acid solvent and contaminated irrigation water near the Luminaires. ËÒÁãªÊÒÃà¤ÁÕહ »ØÂ, ÂÒ¡íҨѴÈѵÃپת, »Ù¹¢ÒÇ, ÊÒÃÅÐÅÒ·Õè໹¡Ã´ áÅйéíÒ»¹à»Í¹ÊÒÃà¤ÁÕ ºÃÔàdz·ÕèµÔ´µÑé§â¤Áä¿ NO Make sure the plug is secured tightly and note the ground level. ¾ÅØ¡µÍ§ÂÖ´ÍÂҧṹ˹ÒáÅÐàÊÁ͡Ѻ¼ÔǾ×é¹ To reduce the risk of being constricted The wires attached to this lamp must be effectively fixed to the wall. if the power cord is within reach. à¾×èÍÅ´¤ÇÒÁàÊÕ觵͡Òö١ÊÒÂä¿à¡ÕèÂÇ/ÃÑ´ ÊÒÂä¿·ÕèµÍà¢ÒµÑÇâ¤ÁµÍ§¶Ù¡µÔ´ÂÖ´¡Ñº¼¹Ñ§ÍÂÒ§àÃÕºÃÍ Cable Cable LED Our products are installed with electronic components with the protection against overvoltage according to IEC 61547. The customers have to install the additional overvoltage protection devices (against surge, transients, etc) in their electrical system to avoid the risk of damage. Failing to do so can cause the end of products warranty. ¼ÅÔµÀѳ±¢Í§àÃÒä´ÃѺ¡ÒõԴµÑé§Ãкº»Í§¡Ñ¹áç´Ñ¹ä¿¿Òà¡Ô¹µÒÁÁÒµÃฐÒ¹ IEC 61547 ÅÙ¡¤ÒµÍ§µÔ´µÑé§ÍØ»¡Ã³»Í§¡Ñ¹áç´Ñ¹ä¿¿Òà¡Ô¹à¾ÔèÁàµÔÁ(હ »Í§¡Ñ¹ä¿¡ÃЪҡ ÏÅÏ ) ã¹Ãкºä¿¿Òà¾×èÍËÅÕ¡àÅÕ觤ÇÒÁàÊÕÂËÒ·ÕèÍÒ¨¨Ðà¡Ô´¢Öé¹ ËÒ¡ÅÙ¡¤ÒäÁ·íÒ¡ÒõԴµÑé§à¾ÔèÁ àµÔÁÍÒ¨·íÒãË¡ÒÃÃѺ»ÃСѹÊÔ¹¤ÒÊÔé¹Êشŧ Clean the products regularly to maintain good light output and prolong surface quality . Only use solvent-free cleaning solutions on the products. ·íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ ±à»¹»ÃШíÒà¾×èÍÃÑ¡ÉÒ¤ÇÒÁÊͧÊÇÒ§·Õè´ÕáÅÐÂ×´ÍÒÂؤسÀÒ¾¾×é¹¼ÔÇ ãª¹éíÒÂÒ·íÒ¤ÇÒÁÊÐÍÒ´·ÕèäÁÁÕáÍÅ¡ÍÎÍÅËÃ×͵ÑÇ·íÒÅÐÅÒ¡Ѻ¼ÅÔµÀѳ±à·Ò¹Ñé¹ Do not use a high pressure washer to clean the products. ËÒÁãªà¤Ã×èͧ©Õ´¹éíÒáç´Ñ¹Ê٧㹡Ò÷íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ ± Last Revised On : 20/10/2022 REV.09 4/5 FR-DM-17 REV.03 EFF 15/09/17 LED LED To replace the LED module or the entrire luminaire.Please consult your sales representative. ËÒ¡µÍ§¡ÒÃà»ÅÕè¹ LED module ËÃ×Íâ¤Áä¿â»Ã´µÔ´µÍµÑÇá·¹¢Ò¢ͧ¤Ø³ LED 230 V Environmental protection: Waste electrical products should not be disposed of with household waste. please recycle where facilities exist.check with your local authority or retailer for recycling advice According to directive 2002/96/CE and directive 2012/19/EU Waste Electrical and Electronic Equipment (WEEE). ËÒÁ·Ô駼ÅÔµÀѳ±¹ÕéÃÇÁ¡Ñº¢ÂÐ㹤ÃÑÇàÃ×͹ª¹Ô´Í×è¹æàÁ×èÍÊÔé¹ÊØ´ÍÒÂØ¡ÒÃ㪧ҹâ»Ã´á¡¼ÅÔµÀѳ ±ÍÍ¡ ¨Ò¡¢Í§àÊÕ»ÃÐàÀ·Í×è¹æáÅÐÃÕä«à¤ÔÅÍÂÒ§àËÁÒÐÊÁà¾×èÍʧàÊÃÔÁ¡ÒùíÒ·ÃѾÂҡáÅѺÁÒ㪫éíÒ«Ö觨ЪÇ »Í§¡Ñ¹ÍѹµÃÒµÍÊÔè§áÇ´ÅÍÁËÃ×ÍÊØ¢ÀÒ¾¢Í§Á¹ØÉ·Õèà¡Ô´¨Ò¡¡Ò÷Ô駢ÂÐâ´ÂäÁÁÕ¡ÒäǺ¤ØÁ ÍÒ§ÍÔ§µÒÁÃÐàºÕº 2002/96/CE áÅÐÃÐàºÕº 2012/19/EU Waste Electrical and Electronic Equipment (WEEE). Replacing the LED module ÇÔ¸Õ¡ÒÃà»ÅÕè¹ LED module 1. Contact your sales representative for replacement LED modules. Make sure that the replacement module match the initially supplied module. Note the part number printed on the LED module. àµÃÕÂÁ LED module ã˵ç¡ÑºÃع·ÕèµÍ§¡ÒÃà»ÅÕè¹â´ÂµÃǨÊͺ·ÕèËÁÒÂàÅ¢·Õè¾ÔÁ¾º¹LED modules áÅÐ µÔ´µÍµÑÇá·¹¢ÒÂà¾×èÍÊÑ觫×éÍ LED modules ·ÕèµÍ§¡ÒÃà»ÅÕè¹ 2. The LED module can be replaced by qualified persons using standard tools. ¡ÒÃà»ÅÕè¹ LED module µÍ§·íÒâ´ÂªÒ§¼ÙªíÒ¹Ò­áÅÐãªà¤Ã×èͧÁ×Í·Õèä´ÁÒµÃฐÒ¹ 3. Disconnect power before opening the luminaire housing. µÑ´áËŧ¨ÒÂ信͹·Õè¨Ðà»´µÑÇâ¤Á 4. Replace the old LED module with the new LED module. Reapply thermal interface material as supplied with the new LED module. ¶Í´ LED module ·ÕèªíÒÃØ´ÍÍ¡ ¨Ò¡¹Ñ¹·íÒ¤ÇÒÁÊÐÍÒ´¨Ø´ÇÒ§ËÅÍ´ áÅǨ֧ ·íÒ¡ÒûÃСͺ LED module ãËÁ áÅеͧà»ÅÕè¹ á¼¹Thermal Pad ËÃ×Í Thermal Grease ´Ç·ء¤ÃÑé§ 5. Inspect gaskets and if required replace with new gaskets. Defective luminaire covers must be replaced. Inspect correct wiring of replaced LED module. µÃǨÊͺ»ÃÐà¡ç¹áÅЪÔé¹Êǹ¢Í§µÑÇâ¤Á ¶ÒªíÒÃØ´àÊÕÂËÒÂãË·íÒ¡ÒÃà»ÅÕè¹ãËÁ áÅеÃǨÊͺ¡ÒÃà¢ÒÊÒÂ俢ͧ LED module ·Õèà»ÅÕè¹ãËÁ¶Ù¡µÍ§ËÃ×ÍäÁ 6. Close the luminaire housing before reconnecting power. »´½Ò¤ÃͺÅçͤâ¤Áä¿ãËàÃÕºÃÍÂ¡Í¹à»´ä¿ Last Revised On : 20/10/2022 REV.09 5/5 FR-DM-17 REV.03 EFF 15/09/17 ">

Link público atualizado
O link público para o seu chat foi atualizado.