Unilamp AGAR Bollard Mode d'emploi
PDF
Descarregar
Documento
INSTALLATION MANUAL PRODUCT NAME : AGAR Prismatic - Indirect Light Bollard AGAR Opal - Direct Light Bollard No. Input voltage 1. 220-240V~ 50-60Hz ** * ** IP65 Ordering Code 7123/7124-0-3/4/5-887-XX 7123/7124-0-3/4/5-891-XX 3. 7123/7124-0-3/4/5-506-XX 4. 7123/7124-0-3-902-XX 5. 7123/7124-0-3-905-XX 6. 7123/7124-0-3-505-XX + 2. 220-240V~ 50-60Hz * 1-6 7-8 Light Emitting Diodes (LED) Light Emitting Diodes (LED) 7123/7124-0-3-873-XX 8. 7123/7124-0-3-874-XX Part/ªÔé¹-A - 7. û324 3 û324 3.3 3.2 895 895 3.1 Part/ªÔé¹-B 3.4 û175 û175 AGAR Opal - Direct Light Bollard AGAR Prismatic - Indirect Light Bollard Part/ªÔé¹-B 2 M8x1.25 200 1 50 Cable length 200 mm. ÊÒÂä¿ÂÒÇ 200 ÁÁ. 1.1 û90 û115 û175 3.5 1.2 Last Revised On : 21/07/2022 REV.06 Anchor bolt kit available separately ªØ´ÊÁͽ§¾×é¹ áÍÅâºÅ· ᡨíÒ Ë¹ Ò Ordering Code/ÃËÑÊÊÑ觫×éÍ : 0084-0-9-000-00 1/5 FR-DM-17 REV.03 EFF 15/09/17 4 For Class I 4 For Class II 6 4.3 25 6 6 30 2 Cable size : 3x1.00 mm. Ø8-11.5mm. ¢¹Ò´ÊÒÂä¿ 4.3 5 25 2 Cable size : 2x1.00 mm. Ø8-11.5mm. ¢¹Ò´ÊÒÂä¿ 5.2 4.1 4.2 4.1 4.2 Torque/áçºÔ´ : 6 Nm. 5.1 6 6 For Class II For Class I Part/ªÔé¹-A Part/ªÔé¹-A Warranty void if removed. ÊÔé¹ ÊØ´¡ÒÃÃѺ»ÃСѹ ËÒ¡¶Ù¡á¡ÐÍÍ¡ 6.2 6.3 6.3 Do not cut or disconnect the cable between this area. ËÒÁµÑ ´µ ÍÊÒÂä¿ ºÃÔ àdz¹Õé Torque/áçºÔ´ : 6 Nm. Warranty void if removed. ÊÔé¹ ÊØ´¡ÒÃÃѺ»ÃСѹ ËÒ¡¶Ù¡á¡ÐÍÍ¡ 6.2 Do not cut or disconnect the cable between this area. ËÒÁµÑ ´µ ÍÊÒÂä¿ ºÃÔ àdz¹Õé Torque/áçºÔ´ : 6 Nm. Part/ªÔé¹-B water tight connecting device. 6.1 IP68 Available Separately IP68 water tight connecting device. Use the rubber seal according to the size of the cable àÅ× Í¡ãªÅÙ¡ÂÒ§à¤àºÔ Åá¡Åç ¹´ µÒÁ¢¹Ò´¢Í§ÊÒÂä¿ Cable size : ¢¹Ò´ÊÒÂä¿ µÑǵÍÊÒÂ俻ͧ¡Ñ¹¹éíÒ ¨íÒ˹ÒÂᡵҧËÒ¡ Ordering Code/ÃËÑÊÊÑ觫×éÍ : 0248-0-9-000-00 Separately 6.1 µÑAvailable ÇµÍ ÊÒÂä¿»Í §¡Ñ¹¹éíÒ ¨íÒ Ë¹Ò ÂᡵҧËÒ¡ Rubber seal size ÅÙ¡ ÂÒ§à¤àºÔ Å á¡Åç ¹´·Õè 㪠Ordering Code/ÃËÑÊ ÊÑè§ «×éÍ : 0248-0-9-000-00 9 Cable size Dia Ø8-9 mm. ¢¹Ò´ÊÒÂä¿ L = Brown (ÊÕ¹éíÒ µÒÅ) 5 Part/ªÔé¹-B Cable size Dia Ø10-11.5 mm. 5 Use the rubber seal according to the size of the cable àÅ× Í¡ãªÅÙ¡ÂÒ§à¤àºÔ Åá¡Åç ¹´ µÒÁ¢¹Ò´¢Í§ÊÒÂä¿ Cable size : ¢¹Ò´ÊÒÂä¿ 9 Cable size Dia Ø8-9 mm. ¢¹Ò´ÊÒÂä¿ L = Brown (ÊÕ¹éíÒ µÒÅ) 12 Cable size Dia Ø10-11.5 mm. ¢¹Ò´ÊÒÂä¿ =Green and yellow (ÊÕà¢Õ ÂÇ¡Ñ ºÊÕ àËÅ× Í§) ¢¹Ò´ÊÒÂä¿ N = Blue (ÊÕ¿Ò) Rubber seal size ÅÙ¡ ÂÒ§à¤àºÔ Å á¡Åç ¹´·Õè 㪠12 N = Blue (ÊÕ¿Ò) Make sure that the rubber seal is correctly in place. ÃÐÇÑ § ÅÙ¡ ÂÒ§ËÅØ´ ÍÍ¡¨Ò¡ªØ ´à¤àºÔ Åá¡Åç ¹´ 7 7 1 Make sure that cable glands are fastened. µÍ§¢Ñ ¹Ê¡ÃÙãË á ¹ ¹ ·Ø ¡ µÑ Ç 2 6 10 1 2 6 4 10 4 3 Last Revised On : 21/07/2022 REV.06 3 8 9 Make sure that the rubber seal is correctly in place. ÃÐÇѧ ÅÙ¡ ÂÒ§ËÅØ´ÍÍ¡¨Ò¡ªØ´ à¤àºÔÅá¡Åç ¹ ´ 2/5 8 9 Make sure that cable glands are fastened. µ ͧ¢Ñ ¹Ê¡ÃÙ ãËá¹ ¹·Ø ¡µÑ Ç FR-DM-17 REV.03 EFF 15/09/17 7 Remark : ËÁÒÂà赯 1. Installation should be carried out by a qualified electrician in accordance with appropriate national wiring regulation. ¡ÒõԴµÑé§â¤Áä¿¿ÒáÅÐÍØ»¡Ã³ ¤ÇôíÒà¹Ô¹¡ÒÃâ´ÂªÒ§ä¿¿Ò ·ÕèÁÕ¤ÇÒÁÃÙáÅФÇÒÁªíÒ¹Ò­ 㹡ÒõԴµÑé§ÍØ»¡Ã³ä¿¿Ò â´Â੾ÒеÒÁÁÒµÃฐÒ¹¢Í§¡ÒÃä¿¿Ò 2. Disconnect the power before changing the lamp. »´ÊÇÔ·ªä¿·Ø¡¤ÃÑ駷Õèà»ÅÕè¹ËÅÍ´ä¿ 3. For class 1 luminaires,the installation must be completed with earthing. ÊíÒËÃѺâ¤ÁÃع·Õè¶Ù¡Í͡ẺáÅШѴäÇã¹»ÃÐàÀ·¢Í§¡Òûͧ¡Ñ¹ä¿ÃÑèÇ ÃдѺ1 ¡ÒõԴµÑ駵ͧµÍÊÒ´ԹµÒÁÁÒµÃฐÒ¹¤ÇÒÁ»ÅÍ´ÀÑ 4. Do not exceed the maximum wattage. ËÒÁãªËÅÍ´ä¿·ÕèÁÕ¢¹Ò´Çѵµà¡Ô¹¡ÇÒ·ÕèÃÐºØ ËÃ×ÍãªËÅÍ´¼Ô´»ÃÐàÀ· 5. Don't touch LED while maintaining or cleaning. ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED ¢³ÐºíÒÃاÃÑ¡ÉÒ ËÃ×Í·íÒ¤ÇÒÁÊÐÍÒ´ Installation complete ¡ÒõԴµÑé§àÊÃç¨ÊÁºÙó Warning : ¢Í¤ÇÃÃÐÇѧ 1. The manufacturer will not be liable or held responsible for any incorrect installation, misuse or improper use and unauthorised modification to the fittings. Failure to comply with mentioned warning may cause serious damage or serious injury to persons, animals or objects. If any modification is required please consult your dealer for the details. ·Ò§¼Ù¼ÅÔµäÁÊÒÁÒöÃѺ¼Ô´ªÍºã¹¤ÇÒÁàÊÕÂËÒÂã´æ·Õèà¡Ô´¨Ò¡¡ÒõԴµÑé§äÁ¶Ù¡ÇÔ¸Õ, 㪧ҹ¼Ô´»ÃÐàÀ·ËÃ×Í´Ñ´á»Å§µÑÇâ¤Áã¹·Ø¡¡Ã³Õ «Öè§ ÊÔ觼Դ»¡µÔàËÅÒ¹Õé ÍÒ¨·íÒãËà¡Ô´ÍѹµÃÒ¡Ѻ ¤¹ ÊÑµÇ ÊÔ觢ͧ ËÒ¡Á Õ¢ÍʧÊÑÂËÃ×ÍÁÕ¤ÇÒÁµÍ§¡ÒûÃѺᵧµÑÇâ¤Á ãËàËÁÒÐÊÁ¡Ñº¡ÒÃ㪧ҹ ¡Ãس ÒµÔ´µÍµÑÇá·¹¨íÒ˹ÒÂËÃ×ͼټÅÔµ 2. Where damage has occured to the fittings, please make the replacement with standard parts before use. 㹡óշÕèÁÕªÔé¹Êǹ»ÃСͺã´à¡Ô´¤ÇÒÁàÊÕÂËÒ¡Ãس Òà»ÅÕ蹪Ôé¹ÊǹãËÁ¡Í¹¡ÒÃ㪧ҹ·Ø¡¤ÃÑé§ à¾×èͤÇÒÁ»ÅÍ´ÀÑ For 1-10V dimming and DALI system. ÊíÒËÃѺÃкº´ÔÁ1-10V áÅÐÃкºDALI A A = 38-40 mm. B = 8-10 mm. C = 30-32 mm. Cable Size/¢¹Ò´ÊÒÂä¿ : 5x1.00 mm.2 Ø7.1-13 mm. B C Green/Yellow (ÊÕà¢ÕÂÇ/ÊÕàËÅ×ͧ) : Brown (ÊÕ¹éíÒµÒÅ) : L Blue (ÊÕ¹éíÒà§Ô¹) : N White (ÊÕ¢ÒÇ) : + (DA1) Black (ÊÕ´íÒ) : - (DA2) IP68 water tight connecting device 5 Pole.Cable Diameter 7.1-13 mm. Available Separately/µÑǵÍÊÒÂ俻ͧ¡Ñ¹¹éíÒ ¨íÒ˹ÒÂᡵҧËÒ¡ Ordering Code : 0413-0-9-000-00 Last Revised On : 21/07/2022 REV.06 3/5 FR-DM-17 REV.03 EFF 15/09/17 For Class I Cable Size/¢¹Ò´ÊÒÂä¿ : 3x1.00 mm.2 Ø8-11.5 mm. For Class II Cable Size/¢¹Ò´ÊÒÂä¿ : 2x1.00 mm.2 Ø8-11.5 mm. In case the supply cable is exposed to sunlight use UV resistant cable. ¡Ã³Õ·ÕèÁÕ¡ÒõԴµÑé§â¤Á俹͡ÍÒ¤Òà ËÃ×Íâ¤Áä¿·ÕèÁÕ¡ÒÃá¼ÃѧÊÕÂÙÇÕ ÊÒÂ俵ͧÊÒÁÒö»Í§¡Ñ¹ ËÃ×Í ÁÕ¡Òûͧ¡Ñ¹äÁã˶١ÃѧÊÕÂÙÇÕä´ Do not touch the LED because it may shorten the life time or the LED can be breaking down. ËÒÁÊÑÁ¼ÑÊËÅÍ´ LED â´Âà´ç´¢Ò´ à¾ÃÒШзíÒãËËÅÍ´àÊ×èÍÁÊÀÒ¾ NO Any damaged safety glass cover must be replaced only with the original spare part. àÁ×èÍ¡ÃШ¡à¡Ô´¤ÇÒÁàÊÕÂËÒ à¾×èͤÇÒÁ»ÅÍ´ÀѤÇÃÊÑè§ÍÐäËÅá·¨Ò¡¼Ù¼ÅÔµà·Ò¹Ñé¹ NO LED Not using chemical compounds and aggressive agents such as , weed repellents fertilizers , acid solvent and contaminated irrigation water near the Luminaires. ËÒÁãªÊÒÃà¤ÁÕહ »ØÂ, ÂÒ¡íҨѴÈѵÃپת, »Ù¹¢ÒÇ, ÊÒÃÅÐÅÒ·Õè໹¡Ã´ áÅйéíÒ»¹à»Í¹ÊÒÃà¤ÁÕ ºÃÔàdz·ÕèµÔ´µÑé§â¤Áä¿ Our products are installed with electronic components with the protection against overvoltage according to IEC 61547. The customers have to install the additional overvoltage protection devices (against surge, transients, etc) in their electrical system to avoid the risk of damage. Failing to do so can cause the end of products warranty. ¼ÅÔµÀѳ±¢Í§àÃÒä´ÃѺ¡ÒõԴµÑé§Ãкº»Í§¡Ñ¹áç´Ñ¹ä¿¿Òà¡Ô¹µÒÁÁÒµÃฐÒ¹ IEC 61547 ÅÙ¡¤ÒµÍ§µÔ´µÑé§ÍØ»¡Ã³»Í§¡Ñ¹áç´Ñ¹ä¿¿Òà¡Ô¹à¾ÔèÁàµÔÁ(હ »Í§¡Ñ¹ä¿¡ÃЪҡ ÏÅÏ ) ã¹Ãкºä¿¿Òà¾×èÍËÅÕ¡àÅÕ觤ÇÒÁàÊÕÂËÒ·ÕèÍÒ¨¨Ðà¡Ô´¢Öé¹ ËÒ¡ÅÙ¡¤ÒäÁ·íÒ¡ÒõԴµÑé§à¾ÔèÁ àµÔÁÍÒ¨·íÒãË¡ÒÃÃѺ»ÃСѹÊÔ¹¤ÒÊÔé¹Êشŧ Clean the products regularly to maintain good light output and prolong surface quality . Only use solvent-free cleaning solutions on the products. ·íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ ±à»¹»ÃШíÒà¾×èÍÃÑ¡ÉÒ¤ÇÒÁÊͧÊÇÒ§·Õè´ÕáÅÐÂ×´ÍÒÂؤسÀÒ¾¾×é¹¼ÔÇ ãª¹éíÒÂÒ·íÒ¤ÇÒÁÊÐÍÒ´·ÕèäÁÁÕáÍÅ¡ÍÎÍÅËÃ×͵ÑÇ·íÒÅÐÅÒ¡Ѻ¼ÅÔµÀѳ±à·Ò¹Ñé¹ Last Revised On : 21/07/2022 REV.06 4/5 FR-DM-17 REV.03 EFF 15/09/17 Do not use a high pressure washer to clean the products. ËÒÁãªà¤Ã×èͧ©Õ´¹éíÒáç´Ñ¹Ê٧㹡Ò÷íÒ¤ÇÒÁÊÐÍÒ´¼ÅÔµÀѳ ± LED LED To replace the LED module or the entrire luminaire.Please consult your sales representative. ËÒ¡µÍ§¡ÒÃà»ÅÕè¹ LED module ËÃ× Íâ¤Áä¿â»Ã´µÔ´µÍµÑÇá·¹¢Ò¢ͧ¤Ø³ LED 230 V Environmental protection: Waste electrical products should not be disposed of with household waste. please recycle where facilities exist.check with your local authority or retailer for recycling advice According to directive 2002/96/CE and directive 2012/19/EU Waste Electrical and Electronic Equipment (WEEE). ËÒÁ·Ô駼ÅÔµÀѳ±¹ÕéÃÇÁ¡Ñº¢ÂÐ㹤ÃÑÇàÃ×͹ª¹Ô´Í×è¹æàÁ×èÍÊÔé¹ÊØ´ÍÒÂØ¡ÒÃ㪧ҹâ»Ã´á¡¼ÅÔµÀѳ ±ÍÍ¡ ¨Ò¡¢Í§àÊÕ»ÃÐàÀ·Í×è¹æáÅÐÃÕä«à¤ÔÅÍÂÒ§àËÁÒÐÊÁà¾×èÍʧàÊÃÔÁ¡ÒùíÒ·ÃѾÂҡáÅѺÁÒ㪫éíÒ«Ö觨ЪÇ »Í§¡Ñ¹ÍѹµÃÒµÍÊÔè§áÇ´ÅÍÁËÃ×ÍÊØ¢ÀÒ¾¢Í§Á¹ØÉ·Õèà¡Ô´¨Ò¡¡Ò÷Ô駢ÂÐâ´ÂäÁÁÕ¡ÒäǺ¤ØÁ ÍÒ§ÍÔ§µÒÁÃÐàºÕº 2002/96/CE áÅÐÃÐàºÕº 2012/19/EU Waste Electrical and Electronic Equipment (WEEE). Replacing the LED module ÇÔ¸Õ¡ÒÃà»ÅÕè¹ LED module 1. Contact your sales representative for replacement LED modules. Make sure that the replacement module match the initially supplied module. Note the part number printed on the LED module. àµÃÕÂÁ LED module ã˵ç¡ÑºÃع·ÕèµÍ§¡ÒÃà»ÅÕè¹â´ÂµÃǨÊͺ·ÕèËÁÒÂàÅ¢·Õè¾ÔÁ¾º¹LED modules áÅÐ µÔ´µÍµÑÇá·¹¢ÒÂà¾×èÍÊÑ觫×éÍ LED modules ·ÕèµÍ§¡ÒÃà»ÅÕè¹ 2. The LED module can be replaced by qualified persons using standard tools. ¡ÒÃà»ÅÕè¹ LED module µÍ§·íÒâ´ÂªÒ§¼ÙªíÒ¹Ò­áÅÐãªà¤Ã×èͧÁ×Í·Õèä´ÁÒµÃฐÒ¹ 3. Disconnect power before opening the luminaire housing. µÑ´áËŧ¨ÒÂ信͹·Õè¨Ðà»´µÑÇâ¤Á 4. Replace the old LED module with the new LED module. Reapply thermal interface material as supplied with the new LED module. ¶Í´ LED module ·ÕèªíÒÃØ´ÍÍ¡ ¨Ò¡¹Ñ¹·íÒ¤ÇÒÁÊÐÍÒ´¨Ø´ÇÒ§ËÅÍ´ áÅǨ֧ ·íÒ¡ÒûÃСͺ LED module ãËÁ áÅеͧà»ÅÕè¹ á¼¹Thermal Pad ËÃ×Í Thermal Grease ´Ç·ء¤ÃÑé§ 5. Inspect gaskets and if required replace with new gaskets. Defective luminaire covers must be replaced. Inspect correct wiring of replaced LED module. µÃǨÊͺ»ÃÐà¡ç¹áÅЪÔé¹Êǹ¢Í§µÑÇâ¤Á ¶ÒªíÒÃØ´àÊÕÂËÒÂãË·íÒ¡ÒÃà»ÅÕè¹ãËÁ áÅеÃǨÊͺ¡ÒÃà¢ÒÊÒÂ俢ͧ LED module ·Õèà»ÅÕè¹ãËÁ¶Ù¡µÍ§ËÃ×ÍäÁ 6. Close the luminaire housing before reconnecting power. »´½Ò¤ÃͺÅçͤâ¤Áä¿ãËàÃÕºÃÍÂ¡Í¹à»´ä¿ Last Revised On : 21/07/2022 REV.06 5/5 FR-DM-17 REV.03 EFF 15/09/17 ">

Link público atualizado
O link público para o seu chat foi atualizado.