How to perform the maintenance of the boiler?

Monthly maintenance involves emptying the ash pan. Annual maintenance requires cleaning the heat exchanger tubes, the burner, the suction turbine, the igniter, and the Lambda probe, as well as lubricating moving parts. Use the "Manual" mode on the control panel to individually activate cleaning mechanisms during these operations.

A U

James A.

How to perform maintenance on the boiler?

Maintenance includes emptying the ash pan monthly and performing an annual cleaning of the heat exchanger, firebox, suction turbine, and igniter. Use the 'Manual' mode on the control panel to individually activate functions like the grate or turbulators for cleaning. Ensure the unit is unplugged and cooled before any intervention.

I I

Michael I.

Where and how to install the outdoor temperature sensor?

The outdoor sensor must be placed at about 1/3 of the building height (minimum 2 m above the ground) on the coldest wall (North or North-East), away from heat sources. The connection cable must exit downwards to prevent moisture entry, and the sensor has no polarity.

L I

John L.

What are the installation requirements and specifications for the outdoor sensor?

The outdoor sensor (PT1000 type, non-polarized) should be installed at least 2 m above the ground (about 1/3 of the building height) on the North or North-East wall, avoiding heat sources, with the cable exiting downwards.