What causes a 'Product Alarm' and how can it be acknowledged?

A 'Product Alarm' occurs when a new start signal is detected while the previous print-apply process is still in progress. It can be acknowledged by pressing keys 2 and 3 simultaneously on the control panel.

D P

Mary D.

How to resolve the 'Product Alarm' warning on the XPA 93x labeling system?

The 'Product Alarm' occurs when a new start signal is detected while a previous process is still running. It can be acknowledged by pressing keys 2 and 3 simultaneously on the control panel.

F Q

Jennifer F.

What are the functional key combinations for the XPA 93x machine?

The control panel supports several combinations: 1+3+4 for access codes, 3+4 for label gap measurement, 2+3 for slow label feed, 1+2+3 for restart, and 2+4 for standalone mode.

V E

Linda V.

How to configure the ribbon transfer alarm?

Use the 'System > Print Ctrl > Ribbon Alarm Stop' setting to enable the alarm/stop function, and define the trigger threshold via 'Min Ribbon Diam'.

J L

John J.

How to configure the label dispensing delay and navigate the dispenser menu structure?

The dispensing delay is adjusted via the 'Distributeur > Signal Démarrage > Délai distribut.' menu or a shortcut icon on the control panel. The Dispenser menu is organized into sub-menus: Mode distri. (Type and InitFeedback), Vitesse (Print and Feed speeds), Signal Démarrage (Delay, Exit, Application mode, etc.), Position distri., Plaque distri., Dist.tête/plaque, and RAZ Compt. Distri.

J L

John J.

How to configure the label dispense delay and navigate the dispenser menu?

The 'Délai distribut.' (Dispense Delay) is adjusted via the 'Distributeur > Signal Démarrage' menu or a shortcut icon on the panel. The 'Distributeur' menu includes sub-menus for Dispense Mode (type, feedback), Speed (print, feed), Start Signal (delay, exit, application mode), Dispense Position, Dispense Plate, and counter reset functions.

J L

John J.

How to adjust label distribution timing and navigate the dispenser menu?

Adjust the 'Délai distribut.' setting within the 'Distributeur > Signal Démarrage' menu. The 'Distributeur' menu also contains settings for distribution mode, speed, start signal timing, and plate position.