User questions

S B

Robert S.

How to resolve a smoke temperature fault exceeding 100 °C?

Inspect the insulated hoses to ensure normal water circulation in the condenser. Clean the heating body and the condenser. Verify that the turbulators are present and in good condition within the smoke tubes. Check the condition of the burner. The safety thermostat can be manually reset after removing its cap.

U C

Patricia U.

What steps should be taken if the smoke temperature exceeds 100 °C?

Verify that the water circulation in the condenser is normal by checking the insulated hoses. Clean the heating body and the condenser, and ensure the turbulators are present and in good condition. Check the condition and operation of the burner. The safety thermostat can be manually reset after removing its cap. Do not short-circuit safety thermostats.

S B

Robert S.

What checks should be performed in case of a flue gas temperature fault?

Verify the water circulation in the condenser, clean the heating body and the condenser, ensure that the turbulators are present in the flue tubes and in good condition, and check the burner. The safety thermostat can be manually reset after removing its cap. Safety thermostats must never be bypassed.

U C

Patricia U.

What checks are required if the flue gas temperature exceeds 100 °C?

Check the water circulation in the condenser, clean the heating body and the condenser, verify that the turbulators are present and in good condition, and inspect the burner status. The safety thermostat can be manually reset by removing its cap. Do not bypass safety thermostats.

S B

Robert S.

What steps should be taken if there is a flue gas temperature fault?

Check that the water circulation in the condenser is normal via the insulated hoses. Clean the heating body and the condenser, and ensure that the turbulators are present and in good condition in the flue tubes. Inspect the burner's condition.

U C

Patricia U.

How to troubleshoot a flue gas overheating fault?

Verify the water circulation in the condenser and clean the heating body. Ensure the turbulators are properly installed in the flue tubes and check the operation of the burner. The safety thermostat can be manually reset by removing its cap.